INSTRUCTIONS FOR THE INSTALLER

INSTRUCTIONS FOR THE INSTALLER

INSTALLATION

The Purchaser is responsible for the installation of the hob. The Manufacturer does not accept any responsibility for any damage or loss resulting from incorrect installation, and as such this will not covered by the Manufacturer’s Guarantee.

The hob may be installed in any worktop which is heat resistant to a temperature of 100° C, and has a thickness of 25 - 45 mm. The dimensions of the insert to be cut out of the worktop are in shown in Fig. 1.

If the Hob is fitted next to a cabinet on either side, the distance between the Hob and the cabinet must be at least 15 cm (see Fig. 2); while the distance between the hob and the rear wall must be at least 5,5 cm.

The distance between the hob and any other unit or appliance above it (e.g. An ex- tractor hood) must be no less than 70 cm (fig.2).

When there is an accessible space between the built-in hob and the cavity below, a divi- ding wall made of insulating material should

be inserted (wood or a similar material). The wall should be at least 10 mm away from

bottom of the drawer. (fig. 3)

Important - The diagram below shows how the sealant should be applied.

Plan 60

Plan 75

The Hob unit is fitted by attaching the Fixing Clamps supplied, using the holes at the base of the unit.

Fig. 1

accessible space

Fig. 3

Fig. 2