CONNECTION TO THE TERMINALS ON THE TERMINAL BLOCK :

INSTALLATION - ELECTRICAL CONNECTION

CONNECTION TO THE TERMINALS ON THE TERMINAL BLOCK :

To proceed with the connection, you must adhere to the following instructions.

. Before making the connection, make sure that the installation is protected by a suitable fuse, see table on next page, and that it is fitted with wires of a large enough section to supply the appliance normally.

. Choose the supply cord in accordance with the recommendations in the table next page.

. Turn the hob, with the glass side against the worktop, providing you have protected the glass !

. Remove the cover located under the control knobs, fitted by 2 screws at the front.

. Pass the supply cord into the cover hole.

. Pass the supply cord into the clamp.

. Strip the end of each conductor of the supply cord on a 10 mm length, by taking account of the requested length of the cord for the connection on the terminal block.

. The terminal block offers different types of connection. So, in accordance with installation instructions and with the help of shunt bars*, fix the conductors as shown on the chart in next page.

*The shunt bars, placed on the Earth Terminal, allow to make a bridge between two phases.

Note :

Please take care to ensure that the shunt bars do not fall through the hole.

Terminal block

with marks

1 2 3 4 5

Shunts bars

Earth

Terminal

. Screw the cable clamp back.

. Screw the cover hole back.