![CONNECTION TO THE TERMINALS ON THE TERMINAL BLOCK :](/images/new-backgrounds/70503/7050311x1.webp)
INSTALLATION - ELECTRICAL CONNECTION
CONNECTION TO THE TERMINALS ON THE TERMINAL BLOCK :
To proceed with the connection, you must adhere to the following instructions.
. Before making the connection, make sure that the installation is protected by a suitable fuse, see table on next page, and that it is fitted with wires of a large enough section to supply the appliance normally.
. Choose the supply cord in accordance with the recommendations in the table next page.
. Turn the hob, with the glass side against the worktop, providing you have protected the glass !
. Remove the cover located under the control knobs, fitted by 2 screws at the front.
. Pass the supply cord into the cover hole.
. Pass the supply cord into the clamp.
. Strip the end of each conductor of the supply cord on a 10 mm length, by taking account of the requested length of the cord for the connection on the terminal block.
. The terminal block offers different types of connection. So, in accordance with installation instructions and with the help of shunt bars*, fix the conductors as shown on the chart in next page.
*The shunt bars, placed on the Earth Terminal, allow to make a bridge between two phases.
Note :
Please take care to ensure that the shunt bars do not fall through the hole.
Terminal block
with marks
1 2 3 4 5
Shunts bars
Earth
Terminal
. Screw the cable clamp back.
. Screw the cover hole back.
Cord clamp
6 -