Steplll

lf belt is not broken but is stretchedor cut, pull it off the motor pulley (D) .

Lift up end of agitator brush roll . Remove old belt from agitator pul - ley (E) and replace

with new belt . Lettering on belt must be visible .

Stretch belt back and attach to motor pulley.

Step lV

Hold oppositeend of agitator brush roll in place .Push belt end forward, rotating end plate

(F)until it slides into place . Turn agitator, mak - ing sure it rotates freely.

StepV

Positionhood on top of nozzle base .

Turn nozzle over. Replacethe 7 Philipshead screws .

Agitatorbrushroll replacement

Whento replace

Disconnect cleaner from electrical outlet.

When agitator brush roll brushesare worn, the brush roll should be replaced .

To check condition of brushes,move edge of a card acrossbottom

plate while turning brush roll . To maintain cleaningeffectiveness,replacebrush roll if brushesdo not touch card .

What to buy

Whenpurchasingnewagitatorbrushroll,

askfor HOOVERpart no. 59135316.

Howto replace

Disconnect cleaner from electrical outlet.

1 . Removehood, belt and brush roll as s h o w n i n F i g s .2 . 9 I o 2 . 1 1 .

2 . Discardold brush roll .

3 . Replacenew brush roll and belt as shown i n F i g s .2 . 1 2 a n d 2 . 1 3 .

Headlightreplacement

The headlight,located on top of the power nozzle, operateswhen the cleaneris turned on . Use only HOOVERpart no . 59135317, when replacingthe headlight .

Howto replace

Disconnectcleanerfrom electricaloutlet and disconnectpower nozzle from extension wand.

1 . Removethe hood as shown in Fig . 2 . 10 .

2 . Pull old bulb from socket .Push new bulb into socket .

3 . Replacehood .

Page 14
Image 14
Hoover S3825 owner manual Agitatorbrushroll replacement, Headlightreplacement, StepV, Howto replace