THE BRUSHES
When brushes are worn and bristles
do not touch the edge of a card
held across the nozzle, they should
be replaced. Always replace both brushes at the same time to
maintain cleaning efficiency.
TO REPLACE THE BRUSHES
1 (Disconnect the Cleaner from
Electrical Outlet) before re-
placing brushes.
To replace worn brushes,
remove bottom plate, belt and
agitator, following directions given on Page 10. Turn end plate of agitator in opposite
direction until one plate comes off.
3Then pry out end section.
4After end section is removed,, tap
the shaft gently with a hammer.
5Pull shaft from agitator.
Remove brushes by forcing out
with screwdriver. Replace with
new brushes. Slide them into the channel and push in as far as possible.
Replace shaft, lining up the locator on shaft with slot on the
agitator. Replace other end section and end plate and tighten° Replace agitator in
cleaner. (See Page 11.)