The agitator brush roll

The agitator brush roll

When to replace

When agitator brushes are worn, the agitator should be replaced.

To check condition of brushes, discon- nect cleaner from electrical outlet. Move edge of a card across bottom plate while turning agitator. To maintain cleaning effectiveness, replace agitator if brushes do not touch card.

What to buy

Your cleaner requires either a 13” or 15” agitator. When purchasing a new agita- tor, ask for one of the following:

13” - HOOVER part No. 48414110

15” - HOOVER part No. 48414115.

3-24

How to replace

Disconnect cleaner from electrical outlet.

Remove bottom plate, belt and agitator following directions in “The belt” section beginning with Fig. 3-18.

Discard old agitator.

Continue following the directions in “The belt” section to reposition belt, new agitator and bottom plate.

Edge groomer replacement

When to replace

The edge groomers, located on both sides of the nozzle, should be replaced when they are worn.

What to buy

When purchasing edge groomers, ask for HOOVER part No. 39511004.

How to replace

Disconnect cleaner from electrical outlet.

Remove bottom plate as described in “The belt” section (Fig. 3-18).

3-25

Installing groomers

Lift off both old edge groomers and slide new edge groomers into position as shown.

Reposition bottom plate and secure with

(4) Phillips head screws.

Lubrication

The motor is equipped with bearings that contain sufficient lubrication for the life of the motor. The addition of lubricant could cause damage. Therefore, do not add lubricant to motor bearings.

The agitator brush roll is equipped with two ball bearings that should be lubri- cated periodically by a Hoover Factory Service Center or an Authorized Hoover Warranty Service Dealer (Depot).

Thermal protector

An internal thermal protector has been designed into your cleaner to protect it from overheating.

When the thermal protector activates, the cleaner will stop running. If this happens, proceed as follows:

1.Turn the cleaner OFF and discon- nect it from the electrical outlet.

2.Check secondary and final filters for dirt accumulation.

3.Refer to “Clearing blockages” section.

4.When cleaner is unplugged and the motor cools for 30 minutes, the thermal protector automatically resets and cleaning may continue.

If the thermal protector continues to activate after following the above steps, your cleaner may need servicing

(see“Service” section).