8. Startup

15)Has the safety switch been checked for correct operation? Activate the safety switch on top of the spout. The ice machine should shut down immediately. Turn the ice machine off, then back on, to reset.

8. Startup

WARNING

1.All parts are factory-adjusted. Improper adjustments may result in failure.

2.If the unit is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor.

1)Clean the storage bin. (See “III. 2. Maintenance.”)

2)Open the water supply line shut-off valve.

3)Remove the front panel.

4)Move the flush switch on the control box to the “ICE” position.

5)Turn on the power switch on the control box.

6)Replace the front panel in its correct position.

7)Turn on the power supply.