Hoshizaki F-500BAF(-C) III. Cleaning and Maintenance, Cleaning and Sanitizing Instructions

Models: F-500BAF(-C)

1 19
Download 19 pages 51.64 Kb
Page 13
Image 13
III. Cleaning and Maintenance

III. Cleaning and Maintenance

IMPORTANT

Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment.

1. Cleaning and Sanitizing Instructions

WARNING

1.HOSHIZAKI recommends cleaning this unit at least once a year. More frequent cleaning, however, may be required in some existing water conditions.

2.To prevent injury to individuals and damage to the icemaker, do not use ammonia type cleaners.

3.Always wear liquid-proof gloves to prevent the cleaning and sanitizing solutions from coming into contact with skin.

[a]Cleaning Solution

Dilute 4.8 fl. oz. (142 ml) of recommended cleaner Hoshizaki “Scale Away” or “LIME-A-WAY” (Economics Laboratory, Inc.) with 0.8 gallons (3 l) of warm water. This is a minimum amount. Make more solution if necessary.

IMPORTANT

For safety and maximum effectiveness, use the solution immediately after dilution.

[b]Cleaning Procedure

1)Remove the front panel and the top panel, then turn off the power supply.

2)Close the water supply line shut-off valve.

3)Remove all ice from the storage bin.

4)Move the flush switch to the “FLUSH” position.

5)Turn on the power supply and drain out all water from the water line.

6) Turn off the power supply.

Thumbscrews

Spout (B)

Note: This unit is designed to start operating when the

 

 

reservoir is filled with water.

 

 

7) In the storage bin, remove the thumbscrews attaching

Spout Packing (B)

spout (B), then remove spout (B) and spout packing (B).

Fig. 5