6.Water Supply and Drain Connections See Fig. 3
•External filters, strainers or softeners may be required depending on the water quality.
•Water supply inlet is 1/2" female pipe thread (FPT).
•A water supply line
•Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
•Drain outlet for icemaking is 3/4" FPT. The icemaker drain piping connection must be made separately from the bin drain.
•The drains must have 1/4" fall per foot on horizontal runs to get a good flow.
•The drains should not be piped directly to the sewer system. An air gap of a minimum of 2 vertical inches should be between the end of the drain pipe from the icemaker or the ice bin and the floor drain.
•A plumbing permit and services of a licensed plumber may be required in some areas.
Fig. 3
9