[d]Sanitizing Procedure - Initial

[d]Sanitizing Procedure - Initial

1)Close the water supply line shut-off valve.

2)In the storage bin, remove the thumbscrews attaching spout (B), then remove spout (B) and spout packing (B).

3)Remove the thumbscrews attaching spout (A) to the evaporator assembly and

lift off spout (A) and spout packing (A), and the cylinder packing.

4)Pour the sanitizinging solution over the extruding head until the evaporator assembly and the reservoir are filled and the solution starts to overflow into the drain pan.

5)Remove the thumbscrews attaching the bin control assembly to the inside of the bin top panel.

6)Remove the snap pin, shaft and actuator.

Snap Pin

7) Remove the sliding door.

8) Soak the removed parts in .25 gallons (1 l) of sanitizing

Bracket

Shaft

Actuator

Thumbscrews

solution for 10 minutes then wipe them down.

9) Rinse the parts thoroughly.

Fig. 6

IMPORTANT

If the solution is left on these parts, they will rust.

10)Replace all parts in their correct positions.

11)Move the flush switch to the “ICE” position, then turn on the power supply. Replace the top panel and the front panel in their correct positions. Make ice using the solution until the icemaker stops making ice.

[e]Sanitizing Procedure - Final

1)Remove the front panel and the top panel, then turn off the power supply.

2)Move the flush switch to the “FLUSH” position.

3)Turn on the power supply and drain out all water from the water line.

4)Turn off the power supply.

Note: This unit is designed to start operating when the reservoir is filled with water.

5)In the storage bin, remove the thumbscrews attaching spout (B), then remove spout (B) and spout packing (B).