6. ELECTRICAL CONNECTION

6. ELECTRICAL CONNECTION

WARNING

1.Electrical connection must be made in accordance with the instructions on a “WARNING” tag, provided with the pig tail leads in the Junction Box.

2.This icemaker requires a ground that meets the national and local electrical code requirements. To prevent possible electrical shock to individuals or extensive damage to the equipment, install a proper ground wire to the icemaker.

On three phase models, the Voltage Tap Switch in the unit should be positioned to match incoming voltage at start-up. See Fig. 6.

This icemaker must have a separate power supply or receptacle of proper capacity. See the Nameplate.

The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

When excessive voltage is supplied to the Controller Board, the icemaker stops running in 3 seconds. See “10. START UP.”

Usually an electrical permit and services of a licensed electrician are required.