III. CLEANING AND MAINTENANCE INSTRUCTIONS

III. CLEANING AND MAINTENANCE INSTRUCTIONS

IMPORTANT

Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment.

1.CLEANING INSTRUCTIONS WARNING

1.HOSHIZAKI recommends cleaning this unit at least once a year. More frequent cleaning, however, may be required in some existing water conditions.

2.To prevent injury to individuals and damage to the icemaker, do not use ammonia type cleaners.

3.Always wear liquid-proof gloves for safe handling of the cleaning and sanitizing solution. This will prevent irritation from the solution contacting skin.

IMPORTANT

1.The Cleaning Valve is used to provide access to the inside of the Evapo- rator during the cleaning and sanitizing operation. It should be closed for all icemaking operation. The Compressor will not operate unless this valve is completely closed.

2.To open the Cleaning Valve, the Valve Handle should be parallel to the valve body. To close the valve, the Valve Handle should be at a right angle to the valve body.

CLOSED POSITION

OPEN POSITION

 

 