Hoshizaki KM-255BWH, KM-255BAH instruction manual Move the control switch to the OFF position

Models: KM-255BAH KM-255BWH

1 19
Download 19 pages 10.86 Kb
Page 18
Image 18

13)Move the control switch to the OFF position.

14)Reconnect the suction hose and harvest water valve hose.

15)Close the potable water supply line drain valve.

16)Remove all ice from the storage bin and clean the bin.

17)Turn off the power supply at the breaker box.

18)If the icemaker is water cooled, proceed to the next section to drain the condenser. If the icemaker is air cooled, place the panels back in their correct positions. The procedure is complete.

To drain all water from the water-cooled condenser, follow the steps below.

1)Close the water-cooled condenser water supply line shut-off valve.

2)Open the drain valve for the water-cooled condenser water supply line.

3)Allow the line to drain by gravity.

4)Attach compressed air or carbon dioxide supply to the condenser water supply line drain valve.

5)Blow the water supply line out using compressed air or carbon dioxide until water stops coming out.

6)Disconnect the water inlet and outlet at the condenser.

7)Remove the screws securing the compressor base and the condenser. Carefully slide the refrigeration assembly forward.

8)Attach compressed air or carbon dioxide supply to the condenser and blow out the condenser.

9)Close the condenser water supply line drain valve.

10)Place all removed parts back in their correct positions, and then place the panels back in their correct positions.

18

Page 18
Image 18
Hoshizaki KM-255BWH Move the control switch to the OFF position, Reconnect the suction hose and harvest water valve hose