Burner and nozzle specifications (for 60 cm and 65 cm versions only)
GB
Table 1 |
|
|
|
| Liquid Gas |
|
|
| Natural Gas |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Burner |
| Diameter | Thermal | Thermal | Nozzle | Flow* | Thermal |
| Nozzle |
| Flow* | ||
|
|
| power | power | 1/100 | 1/100 | (g/h) | power |
| 1/100 |
| (l/h) | |
|
|
| kW | kW |
|
|
|
| kW |
|
|
|
|
|
|
| (p.c.s.*) | (p.c.s.*) |
|
|
|
| (p.c.s.*) |
|
|
|
|
|
| (mm) | Reduced | Nominal | (mm) | (mm) | *** | ** | Nominal |
| (mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fast (R) |
| 100 | 0.70 | 3.00 | 39 | 86 | 218 | 214 | 3.00 |
| 132 (H) |
| 286 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Reduced Fast (RR) | 100 | 0.70 | 2.60 | 39 | 80 | 189 | 186 | 2.60 |
| 122 (H) |
| 248 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Semi Fast (S) | 75 | 0.40 | 1.65 | 28 | 64 | 120 | 118 | 1.65 |
| 96 (Y) |
| 157 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Auxiliary (A) | 55 | 0.40 | 1.00 | 28 | 50 | 73 | 71 | 1.00 |
| 79 (6) |
| 95 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Triple Crown (TC) | 130 | 1.50 | 3.30 | 61 | 65x2 | 240 | 236 | 3.60 |
| 103x2 |
| 343 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Double flame | 30 | 0,30 | 0,90 | 27 | 44 | 65 | 64 | 0,90 |
| 74 |
| 86 | |
(DCDR internal) (1) |
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Double | (DCDR |
|
|
| 27 | 44 |
|
|
|
| 74 |
|
|
internal) |
|
|
|
|
|
|
|
|
| ||||
flame (1) |
| 130 | 1,50 | 3,60 |
|
| 262 | 257 | 3,60 |
|
|
| 343 |
| (DCDR | 55 | 60x2 |
| 100x 2 |
| |||||||
|
|
|
|
|
|
|
|
|
| ||||
| external |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 2 nozzle) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Double Flame | 30 | 0.40 | 0.90 | 27 | 44 | 65 | 64 | 0.90 |
| 74 |
| 86 | |
(DCDR Internal) (2) |
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Double Flame | 130 | 1.50 | 3.60 | 55 | 67x2 | 262 | 257 | 3.60 |
| 100x2 |
| 343 | |
(DCDR External) |
|
| |||||||||||
2 nozzle (2) |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Nominal (mbar) |
| 37 |
| 20 |
| |||||
Supply pressures |
| Minimum (mbar) |
| 20 | 25 |
| 17 |
| |||||
|
|
| Maximum (mbar) |
| 35 | 45 |
| 25 |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(1)For
(2)For
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/Kg
*** Butane P.C.S. = 49.47 MJ/Kg Natural P.C.S. = 37.78 MJ/m³
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
5