Hotpoint GB 630 RTX, GX 641 RX, GX 751 RTX Liquid Gas, Data Plate, Electrical, connections

Models: GB 640.1 RX GB 750 X GB 641 X GA 761 RFX GA 640.1 RXGA 641 X GA 750 X GB 630 RTX GA 760 TX GA 630 RTX GX 751 RTX GX 641 RX

1 16
Download 16 pages 30 Kb
Page 6
Image 6
DATA PLATE

GB

 

Burner and nozzle specifications (for 75 cm versions only)

 

 

 

 

 

 

 

Table 1

 

 

 

 

Liquid Gas

 

 

 

 

Natural Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

 

Diameter

Thermal

Thermal

By-pass

Nozzle

Flow*

Thermal

 

Nozzle

 

Flow*

 

 

 

 

 

 

power

power

1/100

1/100

(g/h)

 

power

 

1/100

 

(l/h)

 

 

 

 

 

 

kW

kW

 

 

 

 

 

kW

 

 

 

 

 

 

 

 

 

 

(p.c.s.*)

(p.c.s.*)

 

 

 

 

 

(p.c.s.*)

 

 

 

 

 

 

 

 

 

(mm)

Reduced

Nominal

(mm)

(mm)

***

 

**

Nominal

 

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reduced Fast (RR)

100

0.70

2.60

39

80

189

 

186

2.60

 

122 (H)

 

248

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi Fast (S)

75

0.40

1.65

28

64

120

 

118

1.65

 

96 (Y)

 

157

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (A)

55

0.40

1.00

28

50

73

 

71

1.00

 

79 (6)

 

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Triple Crown (TC)

130

1.50

3.30

61

65x2

240

 

236

3.60

 

103x2

 

343

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ultrarapid (UR)

100

0.70

3.40

39

91

247

 

243

3.40

 

138 (H)

 

324

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi-Fishburner (SP)

0.70

1.50

39

60

109

 

107

1.50

 

88

 

143

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Double Flame

30

0.40

0.90

28

44

65

 

64

0.90

 

70

 

86

 

 

(DCDR Internal) (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Double Flame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(DCDR External)

130

1.50

4.10

61

70x2

298

 

293

4.10

 

114x2

 

390

 

 

2 nozzle (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Double flame

30

0,30

0,90

27

44

65

 

64

0,90

 

69

 

86

 

 

(DCDR internal) (1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Double

 

(DCDR

 

 

 

27

44

 

 

 

 

 

69

 

 

 

 

 

internal)

 

 

 

 

 

 

 

 

 

 

 

 

flame (1)

 

 

130

1,50

4,60

 

 

334

 

329

5,00

 

 

 

476

 

 

 

 

(DCDR

55

70 x 2

 

 

113 x 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

external

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 nozzle)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal (mbar)

 

28-30

 

37

 

20

 

 

 

Supply pressures

 

Minimum (mbar)

 

20

 

25

 

17

 

 

 

 

 

 

 

Maximum (mbar)

 

35

 

45

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)For single-control DRDA (DCDR) burner only

(2)For dual-control DRDA (DCDR) burner only

* At 15°C and 1013 mbar - dry gas

** Propane P.C.S. = 50.37 MJ/Kg

*** Butane P.C.S. = 49.47 MJ/Kg Natural P.C.S. = 37.78 MJ/m³

DATA PLATE

Electrical

see data plate

connections

This appliance conforms to the following

European Economic Community directives:

-2006/95/EEC dated 12/12/06 (Low Voltage) and subsequent amendments

-2004/108/EEC dated 15/12/04 (Electromagnetic Compatibility) and subsequent amendments

- 93/68/EEC dated 22/07/93 and subsequent amendments.

- 2009/142/EEC dated 30/11/09 (Gas) and subsequent amendments.

-2002/96/EC and subsequent amendments.

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

6

Page 6
Image 6
Hotpoint GB 630 RTX, GX 641 RX, GX 751 RTX, GA 630 RTX, GA 760 TX, GB 640.1 RX Liquid Gas, Data Plate, Electrical, connections