Operating Condition

Please operate air conditioner in the correct conditions as follows.

COOL mode operation

DRY mode operation

 

 

Outdoor temperature should be in range of 18

Outdoor temperature should be in range of 18 to 43 ,

to 43 , otherwise it is possible for air conditioner

otherwise it is possible for air conditioner to breakdown.

to breakdown.

 

Room humidity should be lower than 90%.

 

Otherwise, it is possible for air conditioner to dew

 

at air conditioner surface and even drop water af-

 

ter running for so much time. But this is normal.

 

 

 

Power requirement (15Amp/15Amp Circuit)

Rated voltage and voltage range: 230V

10%

The electric components will be damaged when the voltage is too high. If the voltage is too low, the compressor will vibrate violently to damage the refrigerant system and easily cause the compressor and electric components not work.

The ground must be connected.

Special socket must be used. Furthermore, the socket and wiring must conform to Australian National Standards.

And the earthing method must be reliable.

In fixed circuit, there must be electricity leakage protection switch of enough power capacity and air switch with enough space.

Earth wire To ensure the reliable earthing, please do not connect earth wire to the following places:

Water pipe

2