![Technical Data](/images/new-backgrounds/181665/18166559x1.webp)
Technical Data
Data badge
Lower part of front frame and rear of appliance.
Pressure setting |
|
Cat I2H (GB/IE) | G20 @ 20mbar |
Gas category |
|
I2H |
|
Appliance class |
|
Class 3 |
|
Ignition
Mains operated
Oven light
25W
Electrical supply
220 - 240V ~ 50Hz, 44W
Grill |
|
Nominal Rate Qn | 2.4kW |
Injector | 1.12mm |
Spark gap | 3 - 4mm |
Oven
Bray type burner, sheet steel body, stainless steel flame strip
Nominal Rate Qn | 2.5kW |
Injector | 1.25mm |
Spark gap | 3 - 4mm |
Thermostat bypass | 50 |
Oven injector - If the injector is removed or replaced for any reason, it is mandatory to apply Hylomar PL32 or Plasticol X10 sparingly to the thread prior to (re) fitting.
Maximum heat input
Qn 2.5kW
Countries of destination
GB - Great Britain, IE - Ireland
28