Enhancements in Release F.05.05 through F.05.70

Enhancements in Release F.05.05 through F.05.60

Remember to disable LACP on ports that will be configured for Public, Group1, Group2, Private, or Local mode. (Refer to “Operating Rules for Port Isolation” on page 23.)

When you enter the command to enable port isolation, the switch displays a caution and prompts you to indicate how to proceed. Type [Y] to continue with enabling port isolation; [N] to leave port isolation disabled. See the Caution on page 21.

Uplink mode is the default setting for all ports when you enable port-isolation. Since these two ports were not explicitly configured, above, they remain in the Uplink mode (and do not need to be explicitly configured as uplinks).

Figure 9. Example of Port-Isolation ConfigurationMessages Related to Port-Isolation Operation

Message

Meaning

 

 

Port Isolation is

In the switch’s factory-default state or after you execute no port-isolation, you must enable

disabled. It must be

port isolation (by executing port-isolationalone) before entering commands for changing

enabled first.

the mode on one or more ports.

 

 

28