Enhancements in Release F.02.02

 

 

 

New Time Synchronization Protocol Options

HP2512(config)#

timesynctimepSelects TimeP.

HP2512(config)#

ip timepmanual 10.28.227.141Activates TimeP in Manual

 

 

 

mode.

 

 

 

 

 

 

 

 

Figure 100. Example of Configuring Timep for Manual Operation

Changing the TimeP Poll Interval. This command lets you specify how long the switch waits between time polling intervals. The default is 720 minutes and the range is 1 to 9999 minutes. (This parameter is separate from the poll interval parameter used for SNTP operation.)

Syntax: ip timep dhcp interval < 1 . . 9999 > ip timep manual interval < 1 . . 9999 >

For example, to change the poll interval to 60 minutes:HP2512(config)# ip timep interval 60

Disabling Time Synchronization Without Changing the TimeP Configuration. The recommended method for disabling time synchronization is to use the timesync command. This halts time synchronization without changing your TimeP configuration.

Syntax:

no timesync

For example, suppose TimeP is running as the switch’s time synchronization protocol, with DHCP as the TimeP mode, and the factory-default polling interval. You would halt time synchronization with this command:

HP2512(config)# no timesync

If you then viewed the TimeP configuration, you would see the following:Figure 101. Example of TimeP with Time Sychronization Disabled

204