Table
Control panel message | Description | Recommended action | |
|
|
|
|
MEBx selection or exit resulted in a setup | 1. | Reboot the computer. | |
| failure. | 2. | Unplug the power cord, |
|
| ||
|
|
| memory modules, and reboot the |
|
|
| computer. |
|
| 3. | If the memory configuration was |
|
|
| recently changed, unplug the power |
|
|
| cord, restore the original memory |
|
|
| configuration, and reboot the computer. |
|
| 4. | If the error persists, replace the system |
|
|
| board. |
|
|
|
|
BIOS information passed to the MEBx | 1. | Reboot the computer. | |
| resulted in a failure. | 2. | If the error persists, update to the latest |
|
| ||
|
|
| BIOS version. |
|
| 3. | If the error still persists, replace the |
|
|
| system board. |
|
|
|
|
MEBx operation experienced a hardware | 1. | Reboot the computer. | |
| error during communication with ME. | 2. | If the error persists, update to the latest |
|
| ||
|
|
| BIOS version. |
|
| 3. | If the error still persists, replace the |
|
|
| system board. |
|
|
| |
DIMM1 is not installed. | Make sure there is a memory module in the | ||
proper MEBx execution. |
| black DIMM1 socket and that it is properly | |
|
| seated. | |
|
|
| |
Invalid Electronic Serial Number | Electronic serial number is missing. | Enter the correct serial number in Computer | |
|
| Setup. | |
|
|
| |
Memory Parity Error | Parity RAM failure. | Run Computer Setup and Diagnostic utilities. | |
| Remove | ||
| problem. | problem goes away. | |
|
|
|
|
Network Server Mode Active and No | Keyboard failure while Network Server Mode | 1. | Reconnect keyboard with computer |
Keyboard Attached | enabled. |
| turned off. |
|
| 2. | Check connector for bent or missing |
|
|
| pins. |
|
| 3. | Ensure that none of the keys are |
|
|
| depressed. |
|
| 4. | Replace keyboard. |
|
|
| |
Parity Check 2 | Parity RAM failure. | Run Computer Setup and Diagnostic utilities. | |
| Remove | ||
| problem. | problem goes away. | |
|
|
|
|
ENWW | POST Numeric Codes and Text Messages 51 |