| 1 – Quick Reference |
|
|
|
|
| ||||
| Front Panel Menus - At a Glance |
|
| ||||
|
|
|
|
|
|
| |
| Address |
| ADDRESS 7 | Sets the |
|
| |
|
| ‚ | INTF HPIB | Selects an interface (HPIB or RS232) |
| ||
|
| ‚ | BAUDRATE 300 | Selects baud rate (300, 600, 1200, 2400, 4800, 9600) |
| ||
|
| ‚ | PARITY NONE | Selects message parity (NONE, EVEN, ODD, MARK, SPACE) |
| ||
|
| ‚ | FLOW NONE | Selects flow control |
| ||
|
| ‚ | LANG SCPI | Selects language (SCPI or COMP) |
| ||
|
|
|
|
|
|
|
|
| Recall |
| *RCL 0 |
| Recalls instrument state |
|
|
|
|
|
|
|
|
| |
| Shift | Save | *SAV 0 |
| Saves present instrument state |
| |
|
|
|
|
|
| ||
| Shift | Error | ERROR 0 | Displays errors in SCPI error queue |
| ||
|
|
|
|
|
| ||
| Meter |
| 12.000V 0.204A | Measures output voltage and current |
| ||
|
| ‚ | 12.500V MAX | Measures peak output voltage1 |
| ||
|
| ‚ | 1.000V | MIN | Measures minimum output voltage1 |
| |
|
| ‚ | 12.330V HIGH | Measures the high level of a | voltage pulse waveform1 |
| |
|
| ‚ | 0.080V | LOW | Measures the low level of a | voltage pulse waveform1 |
|
|
| ‚ | 12.000V RMS | Measures rms voltage1 |
|
| |
|
| ‚ | 0.350A | MAX | Measures peak output current1 |
| |
|
| ‚ | 0.050A | MIN | Measures minimum output current1 |
| |
|
| ‚ | 0.400A | HIGH | Measures the high level of a | current pulse waveform1 |
|
|
| ‚ | 0.012A | LOW | Measures the low level of a | current pulse waveform1 |
|
|
| ‚ | 0.210A | RMS | Measures rms current1 |
|
|
| Voltage |
| VOLT 20.000 | Sets the output voltage |
|
| |
|
|
|
|
|
|
| |
| Current |
| CURR 2.000 | Sets the output current |
|
| |
|
|
|
|
|
| ||
| Protect |
| OC | Protection status (example shows overcurrent tripped) |
| ||
|
|
|
|
|
|
| |
| Output |
| *RST |
| Places the dc source in the |
|
‚PON:STATE RST Select the
| ‚ | PROT:DLY 0.08 | Sets the output protection delay in seconds |
| ‚ | RI LATCHING | Sets the remote inhibit mode (LATCHING, LIVE, or OFF) |
| ‚ | DFI OFF | Sets the discrete fault indicator state (ON or OFF) |
| ‚ | DFI:SOUR OFF | Selects the DFI source (QUES, OPER, ESB, RQS, or OFF) |
| ‚ | PORT RIDFI | Sets the output port functions (RIDFI or DIGIO) |
| ‚ | DIGIO 7 | Sets and reads the I/O port value (0 through 7) |
| ‚ | RELAY ON | Sets the output relay state (ON or OFF) 2 |
| ‚ | RELAY NORM | Sets the output relay polarity (NORM or REV) 2 |
Shift | OV | VOLT:PROT 22 | Sets overvoltage protection level |
|
|
|
|
Shift | Input | CURR:RANG HIGH | Sets current range (HIGH, LOW, or AUTO) |
‚CURR:DET ACDC Sets current measurement detector (ACDC or DC)1
Shift | Cal | CAL ON | Accesses calibration menu (See User’s Guide). | |
Use ä | and ã | to select menu parameters. UseMeter to exit any menu and return to metering mode. | ||
1Not available on HP 6631B - 6634B or in Compatibility mode. | 2Not available on HP 6631B. |
13