5 - Front Panel Operation
As previously mentioned, the HP 66332A dc source has the capability of measuring output waveform parameters such as peak, minimum, high level, and low level as illustrated in the following figure.
V or A MAX
46.8 microsecond sampling rate
V or A HIGH
NOTE:
V or A LOW
V or A MIN
100 millisecond acquisition time
Measurement samples may not
coincide with the actual maximum
or minimum point of the waveform.
| Action | Display |
1. | For current measurements, press Shift, Input. Then press ä until you | CURR:RANG AUTO |
| obtain the CURR:RANG AUTO command. Press Enter to activate |
|
| autoranging. Two other selections are also available. Select the High |
|
| range when measuring currents above 20 mA. Select the Low range for |
|
| improved resolution when measuring currents below 20 mA. |
|
2. | For output waveform measurements, press Shift, Input. Then press q | CURR:DET ACDC |
| until you obtain the CURR:DET command. Check to make sure that the |
|
| ACDC current detector is selected. This provides the best accuracy for |
|
| waveform measurements. Only select the DC current detector if you are |
|
| making dc current measurements and you require a dc measurement |
|
| offset better than 1mA on the High current measurement range. |
|
Note: In the Low current measurement range, the current detector is fixed at DC. With the current detector in dc, accurate current measurements cannot be made on waveforms with frequency contents over a few kHz.
3.On the Function keypad press Meter and press q repeatedly to access the following measurement parameters:
♦ dc voltage and current | <reading>V <reading>A | |
♦ | peak voltage1 | <reading>V MAX |
♦ | minimum voltage1 | <reading>V MIN |
♦ high level of a voltage pulse waveform1 | <reading>V HIGH | |
♦ low level of a voltage pulse waveform1 | <reading>V LOW | |
♦ | rms voltage1 | <reading>V RMS |
♦ | peak current1 | <reading>A MAX |
♦ | minimum current1 | <reading>A MIN |
♦ high level of a current pulse waveform1 | <reading>A HIGH | |
♦ low level of a current pulse waveform1 | <reading>A LOW | |
♦ | rms current1 | <reading>A RMS |
1HP 66332A only
44