3 - Installation

This rear panel connector, has a fault output port and an inhibit input port. The fault (FLT) output, also referred to as the DFI (discrete fault indicator) signal in the front panel and SCPI commands, is an open collector circuit that pulls the positive output low with respect to the negative (chassis referenced) common. The high impedance inhibit (INH) input, also referred to as the RI (remote inhibit) signal in the front panel and SCPI commands, is used to shut down the power supply output whenever the INH + is pulled low with respect to INH (chassis referenced) common.

The connector accepts wires sizes from AWG 22 to AWG 12. Disconnect the mating plug to make your wire connections.

NOTE: It is good engineering practice to twist and shield all signal wires to and from the digital connectors. If shielded wire is used, connect only one end of the shield to chassis ground to prevent ground loops.

Figure 3-4 shows how you can connect the FLT/INH circuits of the dc source.

In example A, the INH input connects to a switch that shorts the Inhibit pin (+) to common whenever it is necessary to disable output of the unit. This activates the remote inhibit (RI) circuit, which turns off the dc output. The front panel Prot annunciator comes on and the RI bit is set in the Questionable Status Event register. To re-enable the unit, first open the connection between pins INH + and common and then clear the protection circuit. This can be done either from the front panel or over the HP-IB/RS-232.

In example B, the FLT output of one unit is connected to the INH input of another unit. A fault condition in one of the units will disable all of them without intervention either by the controller or external circuitry. The controller can be made aware of the fault via a service request (SRQ) generated by the Questionable Status summary bit. Note that the FLT output can also be used to drive an external relay circuit or signal other devices whenever a user-definable fault occurs.

Digital I/O Connections

As shown in Table 3-3 and Figure 3-5, the FLT/INH connector can also be configured as a digital I/O port. Information on programming the digital I/O port is found in chapter 5 and under [SOURce:]DIGital:DATA and [SOURce:]DIGital: FUNCtion commands in the Programming Guide. The electrical characteristics of the digital connector are described in appendix A.

Table 3-3. FLT/INH DIGital I/O Connector

PIN

FAULT/INHIBIT

DIGITAL I/O

1

FLT Output

Output 0

2

FLT Common

Output 1

3

INH Input

Input/Output 2

4

INH Common

Common

28

Page 28
Image 28
HP 6633B, 6632B, 6631B, 6634B manual Digital I/O Connections, FLT/INH DIGital I/O Connector

6631B, 6633B, 6634B, 6632B specifications

The HP 6632B, 6634B, 6612B, and 6633B are high-performance programmable power supplies that have gained prominence in various testing and measurement applications. These models are part of the HP 6000 series, which is renowned for its reliability and versatility in providing precision power supply solutions.

The HP 6632B offers a dual-output capability, delivering up to 32 volts and 3 amps per channel. It is designed for applications requiring stable and accurate voltage and current supplies. With features like overvoltage protection and short-circuit protection, it ensures the safety of both the device under test and the power supply itself. The programmable voltage and current settings allow operators to automate their testing procedures, increasing efficiency.

The HP 6634B takes performance a step further with multiple outputs, providing up to 32 volts and 5 amps per channel. This model is particularly suited for applications requiring higher current, especially in battery testing and device characterization. The ability to program the device remotely adds an extra layer of usability, making it ideal for integration into automated testing environments.

The HP 6612B model is tailored for users who require a compact and portable power supply solution. It delivers up to 20 volts and 2 amps. Despite its smaller size, it retains essential features like programmable settings and fast transient response, making it suitable for both educational purposes and field testing scenarios.

For users looking for a versatile, multi-channel solution, the HP 6633B presents itself as an excellent choice. This model offers up to 32 volts and 5 amps across multiple outputs. It supports a wide range of programmable features and has an intuitive interface, making it user-friendly for both beginners and experienced engineers. The robust design of the 6633B ensures reliable performance in demanding environments.

All four models utilize advanced linear power supply technology that minimizes ripple and noise, which is critical for sensitive electronic components. Together, these power supplies provide professionals in research, manufacturing, and testing with the precision they need for their experiments and product developments. The combination of programmability, safety features, and high-performance specifications makes the HP 6632B, 6634B, 6612B, and 6633B essential tools for electronic engineers and technicians.