Software Installation and Verification

Installation Verification

Step 6. The link can now be enabled and brought up using the zterm utility:

% zterm

11:34:46 ZCOM Interactive command utility 11:34:46 Primary ZLU is 1001

ZTERM> rc 600 601 ZTERM> cn 600 601 en ZTERM> cn 600 601 ac ZTERM> ex

%

Step 7. The zmntr utility can be used to observe the state of the link:

% zmntr

 

 

 

 

 

 

 

ZMNTR> tt 600

601

 

 

 

 

 

ZLU# Mx p:sc

Terminal Description...

Rx.Mes Tx.Mes Errors E.Rate State.......

0600 00

0:01

LAP-D DCE

0

0

0

0.00%

Up

0601 00

1:01

LAP-D DTE

0

0

0

0.00%

Up

**** ** ** Message totals

0

0

0

NaN % ********

ZMNTR> ex

 

 

 

 

 

 

Step 8. With the zterm utility set as a receiver, test messages are sent from the ZLUs:

% zterm

11:46:56 ZCOM Interactive command utility 11:46:56 Primary ZLU is 1001

ZTERM> rc 600 601 ZTERM> tx 600 50 0 2 2 11:47:14 TX test complete!!!

ZTERM>

NOTE

For this example two fifty-byte messages are transmitted from DCE to

 

DTE.

 

 

22