OPERATION

4.Check water level (A) in each battery cell. Do not charge batteries unless water is slightly covering battery plates (B). If needed, add just enough distilled water to slightly cover plates. DO NOT overfill. Batteries can overflow during charging due to expansion. Replace cell caps before charging (Figure 24).

B

A

FIG. 24

NOTE: The machine will become inoperable once charger is connected.

WARNING: Batteries emit hydrogen gas. Explosion or fire can result. Keep sparks and open flame away. Keep battery compartment open when charging.

8.When disconnecting charger, always unplug charger from wall outlet first.

9.After charging, recheck battery fluid level. If needed, add distilled water to bring level of fluid to bottom of sight tubes. Be certain to replace cell caps securely and to wipe off the top of batteries with a clean cloth.

10.Replace battery compartment hood.

MACHINE MAINTENANCE

5.With charger disconnected from machine, plug charger's power cord into a grounded wall outlet (Figure 25).

Grounded

Grounded Outlet

3 Hole Outlet

 

 

Grounding

Ground Pin

Edge/hole

(120V)

(230V)

FIG. 25

6.Connect battery charger into machine as shown (Figure 26).

FIG. 26

7.Charger will automatically begin charging and automatically shut off when fully charged.

To keep machine in good working condition, simply follow daily, weekly and monthly maintenance procedures.

FOR SAFETY: Before leaving or servicing machine, stop on level surface and turn off machine.

TO ACCESS INTERNAL COMPONENTS

1.Drain recovery and solution tank.

2.Turn main power switch off and disconnect batteries.

FOR SAFETY: When servicing machine, disconnect batteries before working on machine.

3.Remove vacuum hoses from vacuum pickup heads.

4.Remove drain hose from holder and push hose halfway through U±bracket to allow hose slack .

5.Carefully hinge tank over (Figure 27).

FIG. 27

12