OPERATION

FIG. 21

4.Remove recovery tank dome and use a hose to rinse out recovery tank. Be careful not to spray water into standpipe screen.

5.Replace drain hose plug tightly when tank is empty.

DRAINING SOLUTION TANK

To drain unused solution from solution tank, pumpout hose is required (Supplied with machine).

1.Connect pumpout hose to accessory tool coupler at rear of machine (Figure 22).

FIG. 22

2. Hold hose over floor sink or remove recovery tank dome and direct hose into tank.

3. Activate main power and pump switch.

BATTERY CHARGING

The following charging instructions are intended for chargers supplied with machine. Use a battery charger with the following specifications to prevent battery damage.

CHARGER SPECIFICATIONS:

￿OUTPUT VOLTAGE ± 36 VOLTS

￿OUTPUT CURRENT ± 25 AMPS

￿AUTOMATIC SHUT±OFF CIRCUIT

￿FOR LEAD ACID DEEP CYCLE BATTERY CHARGING

NOTE: Recharge batteries ONLY after a total of 30 minutes or more. This will prolong battery life. Never leave batteries discharged for lengthy periods.

WARNING: Batteries emit hydrogen gas. Explosion or fire can result. Keep sparks and open flame away. Keep battery compartment open when charging.

FOR SAFETY: When servicing machine, wear protective gloves when handling batteries and battery cables. Avoid contact with battery acid.

1.Transport machine to a well±ventilated area for charging.

2.Turn main power switch off.

3.Remove battery compartment hood to access batteries (Figure 23).

FIG. 23

Concorde￿ HP Plus (01±00)