HP GS1280 CPU Building Block Modules Mandatory, Supported Configurations, Full Use CPU Building

Models: GS1280

1 59
Download 59 pages 14.69 Kb
Page 10
Image 10

QuickSpecs

HP AlphaServer GS1280 Systems

Systems

Step 3 - CPU Building Block Modules – Mandatory

M=Mandatory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O=Optional

 

 

 

 

 

 

 

 

Supported Configurations

 

 

 

 

 

 

 

 

CPUs

2

4

6

8

10

12

14

16 18 20 22 24 26

28

30

32

36

40

44

48

52

56

60

64

Dual CPU Modules

1

2

3

4

5

6

7

8

9

10 11 12 13

14

15

16

18

20

22

24

26

28

30

32

GS1280 Model 8

M

O

O

O

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

GS1280 Model 16

M

O

O

O

O

O

O

O

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

GS1280 Model 32

M

O

O

O

O

O

O

O O O O

O O

O

O

O

-

-

-

-

-

-

-

-

GS1280 Model 64

-

-

-

-

-

-

-

M

-

-

-

O

-

-

-

O

O

O

O

O

O

O

O

O

Configuration Guidelines

1.CPU Building Blocks with different clock speeds can co-exist in one system, but must be separated into hard partitions where the CPUs have the same speed.

2.CPU Building Block or instant Capacity (iCAP) CPU Building Block Modules type (Tru64 UNIX or OpenVMS) must match the base system operating system selected in Step 2, or purchase a base operating system upgrade license to match the license with the CPU Building Block Module.

Full Use CPU Building

AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1300

3X-KN72D-AB

Block Modules

MHz, Tru64 UNIX SMP License

 

 

AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1300

3X-KN72D-AC

 

MHz, OpenVMS SMP License

 

 

AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1150

3X-KN72C-AB

 

MHz, Tru64 UNIX SMP License

 

 

AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1150

3X-KN72C-AC

 

MHz, OpenVMS SMP License

 

 

 

 

Configuration and Use of instant Capacity (iCAP) CPUs

The instant Capacity (iCAP) program gives HP customers the option to purchase add-on CPU modules at a reduced price and install those modules in systems ready to activate instantly when needed for extra computational capacity. To use the iCAP program for AlphaServers:

1.Order and install iCAP CPU modules along with Full Use CPUs. The total number of Full Use CPU Building Block Modules plus iCAP CPU Building Bock Modules must adhere to the limits outlined above for GS1280 systems.

2.Use the iCAP software (supplied with the iCAP CPU Module) to set iCAP CPUs inactive. As long as the total number of active CPUs does not exceed the number of licensed CPUs owned for the system, the owner may choose which CPUs to designate as iCAP.

3.Inactive iCAP CPUs cannot include the primary CPU, CPUs responsible for hardware interrupts, CPUs being used by an application when configuring iCAP, or a CPU connected to an I/O Building Block Drawer.

4.Activate the iCAP CPUs for First Use when extra capacity is needed, and then promptly purchase the iCAP Enablement (Right-to-Use).

iCAP CPU Building Block Module + iCAP Enablement = Full Use CPU Building Block Module

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 10

Page 10
Image 10
HP GS1280 manual CPU Building Block Modules Mandatory, Supported Configurations, Full Use CPU Building