QuickSpecs

HP AlphaServer GS1280 Systems

Systems

1.One Dual CPU Building Block Module (Step 3)

2.Memory (Step 4)

3.I/O Drawer (Step 5)

a.One Standard I/O Drawer (Master or Expansion), or

b.Shared (up to four hard partitions) access to one High Performance I/O Drawer (Master or Expansion)

4.One local disk (Step 5) or external storage for the system software. Network boot can be used in place of the disk storage.

5.User access via the USB port in a Master I/O Drawer, a network connection (requires a LAN or WAN I/O adapter), or local terminal (requires an async I/O adapter).

6.All systems require the following minimum firmware and software revisions to run hard partitions:

a.Minimum Firmware console rev: V6.5-8

b.Tru64 UNIX: V5.1B + Patch kit - T64V51BB22AS0002-20030415.tar

c.OpenVMS: V7.3-1 + TIMA Kits (available at http://h18003.www1.hp.com/alphaserver/gs1280/gs1280_tech.html):

i.DEC-AVPVMS-VMS731_PARTITIONING-V0100-4.PCSI

ii.AVPVMS-VMS731_PARTITIONING-V0100_CVRLET

iii.AVPVMS-VMS731_PARTITIONING-V0100_SUBFORM

Configuration Guidelines

1.The two processors on a Dual Processor CPU Module cannot be split between hard partitions.

2.The set of processors assigned to a partition must form a continuous rectangle on the system interconnect mesh network.

3.CPU modules in an 8P Building Block Drawer share the same 48v power feed (from a redundant power supply). If the 8P Building Block Drawer contains all or portions of several hard partitions, a power fault in the drawer could affect all the partitions in that drawer. Hard partitions that consist of whole 8P Building Block Drawers limit the risk of a power fault in one drawer to one partition.

4.Base systems include an operating system license (Tru64 UNIX or OpenVMS) that licenses all hardware partitions of the system.

5.The license for an HP software product, the license(s) and license key(s) that represent those licenses, may be applied to any partition (OpenVMS Galaxy instance or hardware partition) within that system. Different versions of the operating system or layered products may be used on different partitions. In this case, the customer must be licensed for the latest version in use. Software products from other suppliers may have different licensing requirements for partitions.

Step 1c - Licensing Systems for Both OpenVMS and Tru64 UNIX

A System requires licenses for both OpenVMS and Tru64 UNIX operating systems, either for dual O/S boot of the entire system or for different operating systems in separate hard partitions. To use a second operating system, order the appropriate base system upgrade license and as many dual CPU SMP licenses as needed.

OpenVMS software base system upgrade for GS1280

QB-63PAQ-AC

Tru64 UNIX software base system upgrade for GS1280

QB-595AN-AB

OpenVMS Alpha dual CPU SMP license for GS1280

QL-MT1A9-6T

Tru64 UNIX Alpha dual CPU SMP license for GS1280

QL-MT4A9-6T

 

 