HP ML330 manual Power Specifications

Models: ML330

1 44
Download 44 pages 40.24 Kb
Page 40
Image 40

QuickSpecs

HP ProLiant ML330 Generation 6

Power Specifications

460W PSU Part Number

 

 

500447-B21

 

 

 

 

 

 

 

 

 

Operational Input Voltage Range

 

90 to 135

 

 

 

 

 

 

 

 

 

(Vrms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency Range (Nominal) (Hz)

 

47 to 66 Hz

 

 

 

 

 

 

 

 

 

Nominal Input Voltage (Vrms)

 

 

 

100

 

115

208

220

230

240

Max Rated Output Wattage Rating

 

 

460

 

460

460

460

460

460

Nominal Input Current (A rms)

 

 

 

10

 

10

5

5

5

5

Max Rated Input Wattage Rating (Watts)

 

760

 

760

700

700

700

700

Max. Rated VA (Volt-Amp)

 

 

 

850

 

850

830

830

830

830

Efficiency (%)

 

 

 

65

 

65

65

65

65

65

Power Factor

 

 

 

0.9

 

0.9

0.9

0.9

0.9

0.9

Leakage Current (mA)

 

 

 

3.5

 

3.5

3.5

3.5

3.5

3.5

Maximum Inrush Current (A peak)

 

 

450

 

450

450

450

450

450

Maximum Inrush Current duration (mS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP 750W Power Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part Number - AC 750W PSU

512327-B21

 

 

 

 

 

 

 

 

 

 

 

 

Input Voltage Range (Vrms)

100 to 240

 

 

 

 

 

 

 

 

 

 

 

 

Frequency Range (Nominal)

50/60

 

 

 

 

 

 

 

 

 

 

 

 

 

(Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Input Voltage (Vrms)

 

100

 

120

 

200

 

208

 

220

 

230

 

240

Maximum Rated Output Wattage

 

750

 

750

 

750

 

750

 

750

 

750

 

750

Nominal Input Current (A rms)

 

8.9

 

7.4

 

4.3

 

4.1

 

3.9

 

3.7

 

3.6

Max Rated Input Wattage Rating

 

857

 

847

 

824

 

825

 

820

 

820

 

820

(Watts)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Rated VA (Volt-Amp)

 

894

 

884

 

859

 

859

 

854

 

854

 

854

Efficiency (%) at Max. Rated

 

87.5

 

88.5

 

91

 

91

 

91.5

 

91.5

 

91.5

Output Wattage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Factor

 

0.97

 

0.97

 

0.97

 

0.97

 

0.97

 

0.97

 

0.97

Leakage Current (mA)

 

0.42

 

0.50

 

0.83

 

0.87

 

0.92

 

0.96

 

1.00

Max. Inrush Current (A peak)

 

30

 

 

30

 

30

 

30

 

30

 

30

 

30

Max. Inrush Current duration

 

20

 

 

20

 

20

 

20

 

20

 

20

 

20

(mS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum British Thermal Unit

 

2925

 

2892

2812

 

2812

 

2797

 

2797

 

2797

Rating (BTU-Hr)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for your need.

The HP Power Advisor is located at: www.hp.com/go/proliant-energy-efficientor www.hp.com/go/hppoweradvisor

DA - 13361 Worldwide QuickSpecs — Version 17 — 3-31-2010

Page 40

Page 40
Image 40
HP ML330 manual Power Specifications