QuickSpecs

HP ProLiant ML330 Generation 6

Technical Specifications

System Unit

Tower Dimensions

7.87 x 16.81 x 24.13 in (200 x 427 x 613 mm)

 

(H x W x D)

 

 

 

(W/O foot stand)

 

 

 

Tower Weight

Maximum:

30 kg

 

(approximate)

(All hard drives, power

 

 

 

supplies and processors

 

 

 

installed)

 

 

 

Minimum:

16 Kg

 

 

(One hard drive, power

 

 

 

supply and processor

 

 

 

installed)

 

 

Input Requirements

Rated Line Voltage

100 to 240 VAC

 

(per power supply)

Rated Input Current

7.1 Amps (at 120VAC) to 3.5 Amps (at 240

 

 

 

VAC)

 

 

Rated Input Frequency

50 to 60 Hz

 

 

Rated Input Power

852 W

 

BTU Rating

Maximum

460W - 1773 BTU / hr (at 120 VAC), 1715 (at

 

 

 

240 VAC)

 

 

 

750W - 2892 BTU / hr (at 120 VAC), 2797 (at

 

 

 

240 VAC)

 

 

 

1200W - 3530 BTU / hr (at 120 VAC), 4600

 

 

 

(at 240 VAC)

 

Power Specifications

To review typical system power ratings use the Power Calculator which

 

 

is available via the online tool located at URL: www.hp.com/go/proliant-

 

 

energy-efficientor www.hp.com/go/hppoweradvisor

 

 

- Click on the system of interest. Example: ML330 G6

 

 

- Follow the instructions of the next screens.

 

Power Supply Output

Rated Steady-State

460 (750) W (at 100 VAC),

 

(per power supply)

Power

460 (750) W (at 200 VAC)

 

 

Maximum Peak Power

460 (750) W (at 100 VAC),

 

 

 

460 (750) W (at 200 VAC)

 

 

 

NOTE: See Power Supply Specifications

 

 

 

tables for complete details on 460W PSU and

 

 

 

optional 750W.

 

System Inlet

Operating

50° to 95° F (10° to 35° C) at sea level with an

 

Temperature

 

altitude derating of 1.8°F per 1,000 ft (1.0° C

 

 

 

per every 305 m) above seal level to a

 

 

 

maximum of 10,000 ft (3050 m) no direct

 

 

 

sustained sunlight . Maximum rate of change

 

 

 

is 18°F/hr (10°C/hr). The upper limit may be

 

 

 

limited by the type and number of options

 

 

 

installed. System performance may be

 

 

 

reduced if operating with a fan fault or above

 

 

 

86°F (30°C).

 

 

Non-Operating

-22° to 140° F (-30° to 60° C)

 

Relative Humidity

Operating

10% to 90% relative humidity (Rh), 82.4°F

 

(non-condensing)

 

(28°C) maximum wet bulb temperature, non-

 

 

 

condensing.

 

 

Non-operating**

10% to 95% relative humidity (Rh), 101.7°F

 

 

 

(38.7°C) maximum wet bulb temperature,

 

 

 

non-condensing.

DA - 13361 Worldwide QuickSpecs — Version 17 — 3-31-2010

Page 41

Page 41
Image 41
HP ML330 manual Technical Specifications