NOTE: AutoBiDi Calibration is the automatic version of this calibration. Try AutoBiDi first before running this manual calibration (see Auto calibrations on page 53).
1.Press the Calibrate key from the Front Page screen, then press Manual Calibrations in the menu.
2.Press Manual BiDi Registration on the menu. The control panel displays this prompt:
Print a manual bidi registration page?
3.Press the Proceed (►) key.
The printer prints the calibration pattern you selected.
4.When the calibration page has printed, the control panel displays this prompt: Bidi registration Head 1: 0
5.Examine the BiDi Registration pattern for the current head, and determine which pattern is the closest to perfectly aligned.
Use a printer’s loupe (10x magnification or higher) to select the pattern, since the lines in the patterns may be difficult to see.
Figure
6.Press the ▲ or ▼ control panel keys repeatedly until the number next to the pattern that is closest to aligned perfectly is displayed.
For example, if pattern +2.0 is the closest aligned, press the ▲ key to change the display to: Bidi registration Head 1: +2
If a printhead is extremely out of alignment, there may be no pattern in alignment. Since the bars are nominally five pixels apart, you can add +5 or
7.Press the ▲ key.
56 Chapter 4 Calibration | ENWW |