Installing the Hardware
4.Unplug the AC power cord from the outlet, and then from the server.
5.Disconnect any peripheral devices from the server.
Installing the Smart Array Controller1.Remove or open the access panel.
2.Select an available
3.Remove the slot cover or open the
4.Slide the controller board along the slot alignment guide, and press the board firmly into the slot so that the contacts on the board edge are properly seated in the system board connector.
5.Secure the controller board in place with the
6.Continue by following the instructions given in “Connecting the Cables.”
Connecting the CablesEach peripheral that is connected to the server must have a unique SCSI ID value, falling in the range from 0 to 15 (except ID 7, which is reserved for controller use). The SCSI ID value determines the priority that is given to the device when it attempts to use the SCSI bus.
On products that support
SCSI buses require termination on both ends to prevent signal degradation. In all Compaq servers and storage systems, and the newer ProLiant systems, the controller, SCSI cable, and backplane already provide this termination.
Internal Cabling1.If the device is not hot pluggable, power down the system.
HP Smart Array 641/642 Controller User Guide |