Installing the Hardware
2.Install drives into the removable media bays on the server. (For additional information about drive installation, consult the documentation that accompanied the drives, and refer to Appendix E.)
NOTE: Drives that are to be grouped in the same array should have the same capacity.
—If the drives are hot pluggable, go to step 3.
—If the drives are not hot pluggable, go to step 4.
3.Attach the internal
Installation of the
4.For each SCSI bus, manually set the SCSI ID on each drive to a unique value in the range of 0 to 15, except 7 (which is reserved for controller use). For detailed instructions, consult the documentation that is provided with the drive.
5.Attach the
The
CAUTION: Cable assembly
1.On the rear of the server, connect the cable to the VHDCI connector on the controller, and then tighten the lock screws on the cable connector.
2.Attach the other end of the cable to the storage enclosure, and then tighten the lock screws on the cable connector.
3.Replace the access panel and secure it with the thumbscrews, as required.
HP Smart Array 641/642 Controller User Guide |