Troubleshooting
| Probable | Recommended | |
Problem | Cause | Solution | |
|
|
|
|
Workstation will not | Wrong memory | 1. | Review the |
start. | modules were used |
| documentation that |
| in the upgrade or |
| came with the system to |
| memory modules |
| determine if you are |
| were installed in the |
| using the correct |
| wrong location. |
| memory modules and to |
|
|
| verify the proper |
|
|
| installation. |
|
| 2. | Observe the beeps and |
|
|
| LED lights on the front of |
|
|
| the workstation. See |
|
|
| “Interpreting Diagnostic |
|
|
| Lights and Audible |
|
|
| Codes” to determine |
|
|
| possible causes. |
|
| 3. If you still cannot resolve | |
|
|
| the issue, contact |
|
|
| Customer Support. |
|
|
|
|
Power LED blinks Red | Memory is installed | 1. | Reseat DIMMs. Power |
five times, once every | incorrectly or is bad. |
| on the system. |
second, followed by a |
| 2. | Replace DIMMs one at |
two second pause, and |
| ||
|
| a time to isolate faulty | |
the workstation beeps |
|
| |
|
| module. | |
five times. |
|
| |
| 3. Replace | ||
|
| ||
|
|
| memory with HP |
|
|
| memory. |
|
| 4. | Replace the system |
|
|
| board. |
|
|
|
|
www.hp.com | Getting Started Guide |