5 Electrical and Reliability Features

5.1 About This Chapter

This chapter describes the electrical and reliability features of the interfaces in the
MC509 module, including:
Extreme Working Conditions
Working and Storage Temperatures and Humidity
Power Supply Features
Reliability Features
EMC and ESD Features

5.2 Extreme Working Conditions

Table 5-1 lists the extreme working conditions for the MC509 module. Using the
MC509 module beyond these conditions may result in permanent damage to the
module.
Table 5-1 Extreme working conditions for the MC509 module
Symbol
Specification
Maximum
Value
Unit
VBAT
External power voltage
5.0
V
VCOIN
Input voltage of standby
power for the RTC
3.15
V
VI
Data pin voltage
3.3
V