HEATING ELEMENT

1.Disconnect power from unit.

2.Shut off incoming water supply.

3.Attach hose to drain connection.

4.Lift manual release lever on relief valve to let air into system or break union on outgoing water line.

5.Drain water from tank.

6.Remove access cover.

7.Disconnect the wires from the heating element terminals.

Thermowell

Wires

8.Unscrew heating element.

9.Withdraw element assembly.

Tank Coupling

Element Assembly

10.Install Teflon tape and insert new heating element. Thermowell must be above the heating element, in the 12 o’clock position.

11.Rewire element; refer to wiring diagram in Section II. Torque screws per chart in back.

12.Reinstall access cover.

13.Fill tank and check around element for any leaks.