W a r n i n g

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer.

2.Before servicing or cleaning the unit, switch power off at ser- vice panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by quali- fied person(s) in accordance with all applicable codes and standards, including fire-rated construction.

4.Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufac- turer’s guideline and safety standards,such as those published by the National Fire Prevention Association (NFPA), and the

American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.

8.Never place a switch where it can be reached from a tub or shower.

9.Install fan at least 5 feet (1.52 m) above the floor.

10.This unit must be grounded.

11.Unit must not be installed in a ceiling thermally insulated to a value greater than R40.

C A U T I O N

1.For general ventilating use only. Do not use to exhaust hazard- ous or explosive materials and vapors.

2.To avoid motor bearing damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

3.DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward.

4.Please read specification label on product for further information and requirements.

W a r n i n g

DISCONNECT ELECTRIC

POWER SUPPLY

AND LOCK OUT

SERVICE PANEL BEFORE

SERVICING UNIT

PREVENTATIVE MAINTENANCE

A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.

TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders.

TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.

METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.

MAINTENANCE

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time.

COOKING AREA

 

Do Not Install Above

 

Or Inside This Area

 

45°

45°

 

 

Cooking

Floor

 

 

 

Equipment

 

2

41718-01 01/28/2008

028_41718_EngS_1.28.08_Arial.indd 2

1/28/08 10:47:06 AM

Page 2
Image 2
Hunter Fan 90054, 90058, 90052 manual R n i n g

90054, 90052, 90058 specifications

The Hunter Fan Company has continually been at the forefront of innovative ceiling fan design, and models 90052, 90053, 90054, and 90058 exemplify this commitment by blending style, performance, and technology.

The Hunter Fan model 90052 is known for its sleek, modern aesthetic and is designed to blend seamlessly into contemporary decor. It features a whisper-quiet motor that provides efficient airflow, ensuring that rooms remain comfortable without the disruptive noise often associated with ceiling fans. With its versatile blade options, the 90052 offers customizable airflow, making it suitable for various room sizes and ceiling heights.

Model 90053 stands out with its vintage-inspired design, harkening back to classic styles while incorporating modern technology. This fan features energy-efficient LED lighting, which not only provides ample illumination but also significantly reduces energy consumption, making it an environmentally friendly choice. The 90053 also includes a remote control for ease of use, allowing homeowners to adjust the fan settings from anywhere in the room.

The Hunter Fan model 90054 takes functionality to new heights with its damp-rated design, making it perfect for use in both indoor and covered outdoor spaces. The fan boasts a robust motor that can withstand varying weather conditions while delivering powerful airflow. Its elegant silhouette and rich finish options make the 90054 a stylish addition to any patio or sunroom, enhancing outdoor living spaces year-round.

Lastly, the Hunter Fan model 90058 impresses with its cutting-edge smart home technology. Equipped with Wi-Fi connectivity, this fan can be controlled via smartphone apps or voice commands through popular digital assistants like Amazon Alexa and Google Assistant. This innovative feature allows for seamless integration into smart home ecosystems, providing ultimate convenience for users.

Each of these models reflects Hunter Fan Company's dedication to quality craftsmanship, innovative design, and energy efficiency. With a variety of styles, sizes, and features available, the 90052, 90053, 90054, and 90058 cater to diverse consumer preferences, making them ideal for enhancing any home environment. With their combination of aesthetic appeal and advanced technology, these ceiling fans continue to set the standard for modern home comfort solutions.