Manuals
/
Hunter Fan
/
Kitchen Appliance
/
Ventilation Hood
Hunter Fan
90052 manual READ and SAVE THESE INSTRUCTIONS, I n s t a l l a t i o n, G u i d e
Models:
90054
90053
90052
90058
1
1
40
40
Download
40 pages
7.47 Kb
1
2
3
4
5
6
7
8
<
>
Troubleshooting
Install
Warranty
Maintenance
Remove the wiring cover screw
Solución de problemas
Turn on the power source
Existing Construction - accessible from above
Attach existing ducting to duct connector. Tape joints
Mark position of screws by using holes as a template
Page 1
Image 1
I n s t a l l a t i o n
G u i d e
ENGLISH
See page 2
Español
Vea la página 21
90052/90053/90054/90058 Saturn
™
Bath Ventilator with Light
READ and SAVE THESE INSTRUCTIONS
41718-01
3/29/2006
41718_EngS_3.29.06.indd 1
3/29/06 10:39:57 PM
Page 2
Page 1
Image 1
Page 2
Contents
90052/90053/90054/90058 Saturn Bath Ventilator with Light
READ and SAVE THESE INSTRUCTIONS
I n s t a l l a t i o n
G u i d e
MAINTENANCE
PREVENTATIVE MAINTENANCE
POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT
W a r n i n g
Check all the parts. If damaged, call 1-888-830-1326 for replacements
Before Installation
Estimated assembly time 30 to 60 minutes
NOTE Remove all packing materials before installation
Remove the wiring cover screw
Remove the motor/blower from the housing
with the side of the housing
Remove the wiring cover
For New Construction - attaching to joist go to step A11, page
Choose Installation Option
New Construction - attaching to joist
Pull wires through the strain relief
A160
Connect wires as shown
on page 17 to attach grille
Go to step
Connect wiring from the motor to the wiring cover plate
Reinstall the motor by inserting the tabs and pushing up
Mark position of screws by using holes as a template
New Construction - suspended between joists
Slide the mounting rails into brackets
1/8” Bit
Install the wiring cover plate. Make sure all wiring
Connect wires as shown
connections are inside the box or under the wiring cover plate
Tighten screws
Reinstall the motor by inserting the tabs and pushing up
Connect wiring from the motor to the wiring cover plate
into position. Make sure the wires are not pinched
between the motor and the housing
NO EXISTING FAN
Existing Construction - accessible from above
EXISTING FAN
Cut out an opening for the housing
Pull wires through the strain relief
C15C16
1/8” Bit
Drill a hole in the center of each outline
Install the wiring cover plate. Make sure all wiring
Connect wires as shown
connections are inside the box or under the wiring cover plate
Connect wiring from the motor to the wiring cover plate
Reinstall the motor by inserting the tabs and pushing up
ON OFF
into position. Make sure the wires are not pinched
between the motor and the housing
Pull wires through strain relief
Existing Construction - accessible only from below
Attach existing ducting to duct connector. Tape joints
Move the housing into position above the ceiling
Install the wiring cover plate. Make sure all wiring
Connect wires as shown
Connect wiring from the motor to the wiring cover plate
the wiring cover plate
Turn on the power source
Attaching the Grille
Connect wiring harness
ON OFF
Slide light mount over posts
Install 2 Max 60 watt A-15 bulbs Not Included
Attach thumbscrews
Align glass dome and push up
Solution
Trouble Shooting
Solution
Solution
Warranty
i n s t a l a c i ó n
G u í a
Español
41718Span3.29.06.indd
PRECAUCIÓN
A D V E R T E N C I A
ADVERTENCIA
Mantenimiento preventivo
Verifique todos los
Antes de la instalación
95044-01-000
95029-01-000
Retire las cubiertas de las puntas de tornillo precargadas
Retire el motor/soplador del alojamiento
Retire el tornillo de la cubierta del cableado
Retire las puntas de tornillo precargadas hasta que
Construcción nueva - fijación a la viga
Escoja la opción de instalación
Tire de los alambres por el aliviador de tensiones
A160
Conecte los alambres como se muestra
Option
en la página 37 para fijar la rejilla
Vaya al paso
ENCENDIDO
APAGADO
Deslice los rieles de montaje en los soportes
Construcción nueva - suspendido entre vigas
1/8 de pulg
Fije los rieles con los tornillos
Conecte los alambres como se muestra
Apriete los tornillos
Negro
Negro
en la página 37 para fijar la rejilla
Vaya al paso
ENCENDIDO
APAGADO
SIN VENTILADOR EXISTENTE
C11 VENTILADOR EXISTENTE
Construcción existente - accesible desde arriba
Recorte una abertura para el alojamiento
broca de 1/8 de pulg
C15C16
Taladre un agujero en el centro de cada perfil
Fije los rieles en los tornillos
Conecte los alambres como se muestra
Apriete los tornillos
Conecte el cableado del motor a la placa de cubierta del cableado
Option
ENCENDIDO APAGADO
C25 C26
Vaya al paso
en la página 37 para fijar la rejilla
Construcción existente - accesible sólo desde abajo
D11 VENTILADOR EXISTENTE
Tire de los alambres por el aliviador de tensiones
Instale los tornillos precargados en la viga o el marco
Conecte los alambres como se muestra
Vaya al paso
Fijación de la rejilla
en la página 37 para fijar la rejilla
ENCENDIDO APAGADO
Instale los tornillos de mano
Deslice el soporte sobre los postes
Instale 2 bombillas A-15 de 60 vatios como máximo No incluidas
Alinee el domo de vidrio y levante
Solución
Solución de problemas
Solución
Solución
2500 Frisco Avenue, Memphis, Tennessee Impreso en China
Garantía