The Husky 1750 PowerWasher requires a 15 amp minimum rated circuit to function properly. It is important that your Husky unit does not share a circuit with any other electrical device. If the circuit is shared, the additional device will create an amperage drain that ultimately causes the Husky to draw more amperage in order to run full force. Eventually the machine overheats and shuts itself down. The Husky shuts down as part of the designed safety feature to protect againts overheating. The same effect occurs when two or more outlets are connected to the same circuit. The diagram below shows outlet 1 and outlet 2 on the same circuit. When asking the customer if they have any other electrical device plugged into the same outlet, make sure you explain to them that it also means that nothing can be plugged into an outlet serviced by the same circuit breaker. In regards to the overheating and restarting, the unit requires a minimum of 45 minute period in which the machine can properly cool.