Husky 1750 PSL warranty Troubleshooting, Problem, Possible Cause, Correction

Models: 1750 PSL

1 32
Download 32 pages 38.58 Kb
Page 24
Image 24
7.0 TROUBLESHOOTING

7.0 TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

CORRECTION

 

 

 

Motor will not start or stops while

GFCI tripped or not reset

P l u g t h e p o w e r c o r d i n t o a n

operating

 

electrical outlet. Press the reset

 

 

button on the GFCI in firmaly and

 

 

release. Red light will be on

 

C ir cuit br eaker tr ipped o r fuse

Disconnect all other loads on the

 

blown in electrical service box

same circuit and reset circuit breaker

 

 

or replace fuse

 

Loose or disconnected plug

Reconnect plug

 

Motor thermal overload feature

Allow unit a cool down period, (20

 

tripped

min. recommended) and then restart

 

 

Use of extension cord not advised

Circuit breaker trips or fuse blown in

Circuit Overload

Check that the circuit is rated 15 amps

fuse box

 

or greater. Disconnect all loads on the

 

 

circuit

 

Extension cord too long or wire size

Use proper extension cord as

 

too small

recommended in Operator's Manual

 

Nozzle partially blocked

Clean nozzle as instructed in Section 5.2

 

Excessive pressure

Reduce pressure by using pressure

 

 

adjustment knob

GFCI trips repeatedly

Incorrect voltage

See Section 3.3

 

Internal short

Call Customer Service Department

Water or oil leaking from bottom of

A small amount of leakage is normal

If excessive l eaking o ccur s cal l

pump

 

Powerwasher Help Line Customer

 

 

Service Department 1-866-211-

 

 

3247

Pr essur e incr eases when gun is

Bypass valve not operating properly

Call Customer Service Department

closed

 

 

Motor running but pump not

Faucet closed

Open faucet

building maximum pressure or has

Unit has been stored in freezing

Thaw out unit completely including

irregular pressure

temperatures

hose, gun and wand

 

 

Water inlet screen clogged

Clean screen. See section 5.4

 

Air in pump

Let pressure washer run with gun

 

 

o p e n a nd wa nd r e mo v e d unt i l

 

 

steady stream of water is released

 

Adjustable pressure knob not set to

Set to maximum position.

 

maximum position

See Section 4.2

 

Suction or discharge valves clogged

C a l l P o w e r w a s h e r H e l p L i n e

 

or worn out

C u s t o m e r S e r v i c e D e p a r t m e nt

 

 

1-866-211-3247

 

By-pass valve not operating effectively

Call Customer Service Department

No intake of chemicals

Injection tube not securely inserted

Push firmly into machine

 

into pressure washer

 

 

Tube cracked or split

Replace tubing

 

Wrong Nozzle setting

Switch nozzle to low pressure

 

Nozzle blocked

Clean nozzle. See Section 5.2

 

Injection tube strainer clogged

Clean strainer

 

Dried chemicals in injector

Dissolve by running warm water

 

 

through the injection tube

Trigger will not move

Gun safety lock engaged

Release safety lock

24