START AND STOP
Start and stop
Start
!WARNING!
Never start the blower if the inspection cover is not closed, is damaged or cannot be closed. (Exception: When the vacuum tube is fitted).
Cold engine
IGNITION:
Set the stop switch to the start position.
CHOKE:
Set the choke control in the choke position
(A).
The choke position is also the automatic start throttle position.
AIR PURGE:
Press the air purge diaphragm repeatedly until fuel begins to fill the diaphragm. The diaphragm need not be completely filled.
IMPORTANT!
Do not pull out the starter cord completely and do not release the starter handle from the fully pulled out position. Doing so will damage the starter
Warm engine
IGNITION:
Set the stop switch to the start position.
CHOKE:
Set the choke control in the choke position and then back again to its original position (B) In this way only the start throttle is applied with no choke.
AIR PURGE:
Press the air purge diaphragm repeatedly until fuel begins to fill the diaphragm. The diaphragm need not be completely filled.
A
B
14 – English