Installation Manual
Hybrid IP-PBX
Main Processing Card
MPR Option Card
Trunk Cards
Extension Cards
Power Supply Units
Optional SD Memory
Cards
PSUs
Available Proprietary Telephones
Abbreviations in this manual
Important Safety Instructions
Installation Manual
For business users in the European Union
For users in Germany only
For users in Finland, Norway and Sweden only
For users in New Zealand only
Important Notice
For users in Australia only
For Future Reference
Installation Manual
Structure of this Manual
About the Other Manuals
About the software version of your Hybrid IP-PBX
Trademarks
Precautions for Users in the United Kingdom
Installation Manual
Table of Contents
Power Failure Connections 205
Information about the Extension Cards 107
Information about the Other Cards 123
Connection of Extensions 136
212
Connection 213
215
220
Section System Outline
System Highlights
System Highlights
PC Phone/PC Console Features
Portable Station PS Features
Hospitality Features
Basic Shelf
Basic System Construction
Construction of the Basic Shelf
System Connection Diagram
Hybrid IP-PBX
DPT
Optional Equipment
Optional Equipment
Model No Model Name Description
DHLC8
PAY8
GW4E
Specifications
General Description
Dimension
Weight when fully
Extension Connection Cable
Mounted
Characteristics
Cards Installed in the Slots of the Hybrid IP-PBX
Maximum Optional Service Cards
System Capacity
Card Type Maximum Number Installed KX-TDA100 KX-TDA200
MPR
LCOT4 LCOT8 LCOT16 DID8 BRI4
BRI8 PRI23 PRI30 IP-GW4 IP-GW4E
Card Type Maximum Number
Cards Mounted on Other Optional Service Cards
Card Type Maximum Number Mounted on KX-TDA100 KX-TDA200
Maximum Terminal Equipment
APT IP-PT
MEC Card Calculation
MEC Card Calculation
Calculation Example KX-TDA100
Equipment Type MEC Figure
Power Supply Unit Selection
Load Figure Calculation
PSU Capacity
Equipment Type Load Figure
Calculation Example KX-TDA200
Specifications
Section Installation
Before Installation
Before Installation
Safety Installation Instructions
Installation Precautions
Before Installation
Unpacking
Installation of the Hybrid IP-PBX
KX-TDA100 KX-TDA200
Names and Locations
Inside View
Opening/Closing the Front Cover
Opening the Front Cover
Closing the Front Cover
Installing/Replacing the Power Supply Unit
Accessories and User-supplied Items
Safety Instructions
Accessories included Screws ×
Installing the Power Supply Unit
Replacing the Power Supply Unit
Replace the PSU
Frame Earth Connection
Connect the frame of the Hybrid IP-PBX to earth
Backup Battery Connection
Backup Power Supply Duration
User-supplied Items
Examples
Connecting Backup Batteries
Installing/Removing the Optional Service Cards
Installing Optional Service Cards
Back Board Release Lever
Covering the Blank Slots
Handling of the Cables
Removing the Optional Service Cards
Types of Connectors
Connector Type Pin Number Used for
CTI-LINK KX-TDA0410
BNC
MPR USB
When connecting a BRI card
When connecting a T1/E1/PRI/IP-GW16/IP-EXT16 card
Attaching a Ferrite Core
When connecting an extension card
Fastening Amphenol Connector
Amphenol Connector Pin Assignment Chart
LCOT4 LCOT8 LCOT16 DID8 DHLC8 DLC8 DLC16 MSLC16 SLC8
Wall Mounting KX-TDA200
Installation of the Hybrid IP-PBX
Wall Mounting KX-TDA100
Wall
Installation of the Hybrid IP-PBX
Floor Standing KX-TDA200 Only
TOP Front
Surge Protector Installation
Installation
Overview
IP-PBX SLT PT
Installation of an Earth Rod
Outside Installation
IP-PBX
Installation of the Hybrid IP-PBX
MPR Card
Information about the Main Processing Card
USB BGM/MOH
Batt Alarm
SD Access
LED Indications
Indication Colour Description
MEC Card KX-TDA0105
RMT Card KX-TDA0196
Information about the Trunk Cards
LED
Amphenol Connector
Signal Name Function
Pin Assignments
Card Status
2 DID8 Card KX-TDA0182
LED Indications
Switch Settings on LCOT8/LCOT16 cards
Switch Type Usage and Status Definition
3 CID/PAY8 Card KX-TDA0189
DIP
4 CID8 Card KX-TDA0193
5 E&M8 Card KX-TDA0184
T1A
R1A
SGA
SGB
LED Indications
Switch Settings
6 T1 Card KX-TDA0187
RJ45 Connector for Extension Use
RJ45 Connector for Trunk Use
Signal Name Level Function
Maximum Cabling Distance of Extension Connection
Sync
BNC TX
7 E1 Card KX-TDA0188
BNC RX
BNC coaxial Connector TX
BNC coaxial Connector RX
8 BRI4 Card KX-TDA0284 and BRI8 Card KX-TDA0288
TX1
RX2
RX1
TX2
Line LED Pattern
Line
Master Clock LED Pattern
OFF
Maximum Cabling Distance of S0 Bus Connection
9 PRI30 Card KX-TDA0290CE/CJ
Switch Settings
Link
Maximum Cabling Distance of Extension Connection
10 PRI23 Card KX-TDA0290
Pin Assignments
Maximum Cabling Distance of Extension Connection
Signal Name Input I/Output O Function
RJ45 Connector 10BASE-T
IP-GW4 Card KX-TDA0480
Alarm
Online
IAM Busy
Data
RJ45 Connector 10BASE-T/100BASE-TX
IP-GW4E Card KX-TDA0484
OFF
IP-GW16 Card KX-TDA0490
LED Indications
Information about the Extension Cards
CSIF4 Card KX-TDA0143 and CSIF8 Card KX-TDA0144
Powh
RJ45 Connector
Powl
DHLC8 Card KX-TDA0170
D2A
D1A
D2B
D1B
LED Indications
3 DLC8 Card KX-TDA0171
Data port 1 Low
4 DLC16 Card KX-TDA0172
D2I
D1I
D2J
D1J
5 SLC8 Card KX-TDA0173
Pin Assignments
EXT-CID Card KX-TDA0168
7 SLC16 Card KX-TDA0174 and MSLC16 Card KX- TDA0175
Ring port Tip port 17-25 Reserved 42-50
IP-EXT16 Card KX-TDA0470
Online
Information about the Other Cards
Accessories included none User-supplied not included none
1 OPB3 Card KX-TDA0190
User-supplied not included Copper wire
2 DPH4 Card KX-TDA0161
Pin Terminal Block
DP4
DP3
DP2
3 DPH2 Card KX-TDA0162
Pin Assignments
Path Doorphone Call Path
4 EIO4 Card KX-TDA0164
Pin Assignments
External Sensor
Connection Diagram
External Relay
ECHO16 Card KX-TDA0166
6 MSG4 Card KX-TDA0191
CTI-LINK Card KX-TDA0410
Link Status
PT-interface CS
Connection of Extensions
DSS Console
Using a Modular T-Adaptor
Parallel Connection of the Extensions
With APT
With DPT
Using an EXtra Device Port
With KX-T7600 Series DPT except KX-T7665
Dptslt
With Other DPT except KX-T7560 and KX-T7565
With KX-T7600 Series DPT except KX-T7600E Series
Digital EXtra Device Port Digital XDP Connection
Back View of DPTs
To TEL To Main Unit
With KX-T7600E Series DPT
Connecting to a Slave DPT
Connecting to a Master DPT
First Party Call Control CTI Connection
RF Specification
Connection of Dect Portable Stations
Overview
CS Cell Station KX-TDA0142CE/KX-TDA0141CE
Equipment Distance
Procedure Overview
Investigate the installation site
Prepare for site survey
Conduct the site survey
Finish the site survey
Mount the CS on the wall
Site Planning
Characteristics of Radio Waves
Understanding Radio Waves
Object Material Transmission Tendency
CS Coverage Area
Radio Signal Strength Levels
Site Survey Preparation
CS installation plan
Example Installing in a Room Separated by Interior Walls
Things to take note
Before Site Survey
Checking the CS ID Number
Assigning the CS ID Number to the PS
CS No
Using the KX-TD7590 To enter letters
Setting and Installing the CS Temporarily for Site Survey
DIP Switch
For users in the United Kingdom
Site Survey Using the KX-TCA255/KX-TD7590
Testing the Radio Signal Strength
PS CH0
Channel no
Referring to the Stored Scan Data
Using the KX-TD7590 Log No
Clearing the Stored Scan Data
After Site Survey
Connecting a Cell Station to the Hybrid IP-PBX
Using a Csif Card
Accessories and User-supplied Items for the CS
User-supplied not included RJ11 connector
Using a DHLC/DLC Card
Connecting the CS
For the KX-TDA0142CE User only
Administrator Level
Using the KX-TCA155/KX-TCA255
Registering the PS
PS Registration
System Lock Password /OK
System Lock Password
Using the KX-TD7580
Setting the PIN for Hybrid IP-PBX
Changing the Display Language of the PS
PS Termination
691
Handset PIN
Testing the Operation
Wall Mounting
Install a screw here 71 mm
Reference for Wall Mounting
KX-TDA0142 Using a Csif Card
KX-TDA0141 Using a DHLC/DLC Card
Connection of 2.4 GHz Portable Stations
CS Cell Station KX-TDA0142/KX-TDA0141
Connection of 2.4 GHz Portable Stations
Using the KX-TD7690
Using the KX-TD7680
Prepare the CS for site survey
Finish the site survey
Site Planning
Object Material Transmission Tendency
CS Coverage Area
Example Installing in a Room Separated by Interior Walls
CS Number Switch Radio Signal Test Switch CS no CS no CS no
Connection of 2.4 GHz Portable Stations
Site Survey
Scan Data No
PS CS NO.1 LEVEL12
Scan Data No
Deleting the Stored Scan Data
After Site Survey
Connecting a Cell Station to the Hybrid IP-PBX
Using a DHLC/DLC Card
Connecting the CS
Entering the System Programming Mode
PT Administrator Level
PS Using the KX-TD7680
System Setting Menu
When the PS has not been registered yet
Setting the System Lock
Setting the PIN for PS Using the KX-TD7680
692
System
Wall Mounting
Reference for Wall Mounting
Installing the Doorphone KX-T30865
Maximum Cabling Distance
Connection
Installation Manual
Connection of Peripherals
Connection of Peripherals
BGM
Connection Charts
Pager
PC/Printer via RS-232C
Pin Assignments
For connecting a printer/PC with a 25-pin RS-232C connector
RS-232C Signals
Signal Ground SG
Receive Data RXD…input
PC/CTI Server via USB version
Vbus
USB D
USB D+
Power Failure Connections
Power Failure Connections
Using Analogue Trunk Card and Extension Card
RJ11 Connector Pin Assignments for Analogue Trunk Card
RJ11 Connector Pin Assignments for Extension Card
PFT Ports 1 Signal Name Function
PFT Ports 3 and 4 for LCOT16 card only Signal Name Function
Switch Settings
Using BRI Card
RJ45 Connector Line 1 Pin Assignments
RJ45 Connector Line 2 Pin Assignments
Starting the Hybrid IP-PBX
Starting the Hybrid IP-PBX
Confirming the Trunk Connection
RUN
Section Guide for the KX-TDA Maintenance Console
KX-TDA Maintenance Console*1
Overview
Connection
Connection
Serial Interface Connection
LAN Connection via CTI-LINK Card
External Modem Connection
SD TXD RD RXD DR DSR ER DTR
Installation of the KX-TDA Maintenance Console
Installing and Starting the KX-TDA Maintenance Console
Password Security
System Requirements
Installing the KX-TDA Maintenance Console
Start the KX-TDA Maintenance Console from the Start menu
When country/area data do not match
Installation of the KX-TDA Maintenance Console
Section Troubleshooting
Troubleshooting
Installation
Problem Probable Cause Solution
Cause
Trunk is connected to the T2/R1
Operation
Problem Probable Cause Solution
Using the Reset Button
Operation
Error Log Display Format
Troubleshooting by Error Log
Description
Description
List of Errors and Solutions
Error Code Error Message
SLC, CSIF, LCOT, T1, E1
BRI, PRI, OPB3, E&M, IP
System Start-up and On-line Operation
Probable Cause Solution
Probable Cause Solution
ROM NG
CSIF, T1, E1, BRI, PRI
OPB3, CTI-LINK, E&M
RAM NG IP-GW, DID, SLC8, IP
MPR-LPR CSIF, T1, E1, BRI, PRI
IP-GW Sdram
IP-GW Dpram
IP-PT SUB-CPU
Probable Cause Solution
Probable Cause Solution
Section Appendix
New Contents
Changed Contents
Revision History
Pmpr Software File Version
Pmpr Software File Version
Pmpr Software File Version
Index
Numerics
PSU
PSU-L PSU-M PSU-S
Index
62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan