2.7.2Parallel Connection of the Extensions

2.7 Connection of Extensions

2.7.2Parallel Connection of the Extensions

Any SLT can be connected in parallel with an APT or a DPT as follows.

Note

In addition to an SLT, an answering machine, a fax machine or a modem (PC) can be connected in parallel with an APT or a DPT.

With APT

For parallel connection, eXtra Device Port (XDP) mode must be disabled for that port through system programming. Refer to "1.10.9 Parallelled Telephone" and "2.1.1 Extension Port Configuration" in the Feature Guide for further information.

To DHLC8 card With APT

4-conductor wiring cord Connect pins "T", "R", "D1", With DPT and "D2".

Modular

T-Adaptor

2-conductor wiring cord Connect pins "T" and "R".

APT

SLT

With DPT

Parallel mode or eXtra Device Port (XDP) mode can be selected through system programming.

If XDP mode is enabled through system programming, parallel connection is not possible. Refer to "1.10.9 Parallelled Telephone" and "2.1.1 Extension Port Configuration" in the Feature Guide for further information.

Using a Modular T-Adaptor

To DHLC8 card Using a Modular T-Adaptor

4-conductor wiring cord Connect pins "D1" and "D2".

Modular

T-Adaptor

2-conductor wiring cord Connect pins "T" and "R".

DPT

SLT