Panasonic KX-TDA100 Example Installing in a Room Separated by Interior Walls, Installation Manual

Models: KX-TDA100

1 248
Download 248 pages 58.62 Kb
Page 180
Image 180
180 Installation Manual

2.9 Connection of 2.4 GHz Portable Stations

one CS becomes weak. However, if a PS moves away from a CS and there are no CSs available for handover, the PS may go out of range and the call could be lost.

If the signal from the CS fades, due to the structure of the building, there may be some handover delay. The user will hear a range warning before handover in this case. This also applies in the case of interference from 2.4 GHz apparatus.

Example: Installing in a Room Separated by Interior Walls

Things to take note of:

The room is separated by interior walls.

The room is surrounded by concrete walls.

CS installation plan:

The coverage area of each CS will not extend as far as when there are no obstacles, because the radio signals will be weakened by separating walls. Therefore, you will need 5 CSs to cover the entire room.

150 m

70 m

CS no. 1

CS no. 2

CS no. 5

CS no. 3

CS no. 4

180 Installation Manual

Page 180
Image 180
Panasonic KX-TDA100 Example Installing in a Room Separated by Interior Walls, Things to take note of, CS installation plan