Installation Manual
Hybrid IP-PBX
 Main Processing Card
MPR Option Card
Trunk Cards
Extension Cards
 Power Supply Units
Optional SD Memory
Cards
PSUs
 Available Proprietary Telephones
Abbreviations in this manual
 Important Safety Instructions
 Installation Manual
 For business users in the European Union
For users in Germany only
 For users in Finland, Norway and Sweden only
For users in New Zealand only
Important Notice
For users in Australia only
 For Future Reference
 Installation Manual
 Structure of this Manual
About the Other Manuals
About the software version of your Hybrid IP-PBX
Trademarks
 Precautions for Users in the United Kingdom
 Installation Manual
 Table of Contents
 Power Failure Connections 205
Information about the Extension Cards 107
Information about the Other Cards 123
Connection of Extensions 136
 212
Connection 213
215
220
 Section System Outline
 System Highlights
System Highlights
 PC Phone/PC Console Features
Portable Station PS Features
Hospitality Features
 Basic Shelf
Basic System Construction
Construction of the Basic Shelf
 System Connection Diagram
Hybrid IP-PBX
 DPT
 Optional Equipment
Optional Equipment
Model No Model Name Description
DHLC8
 PAY8
 GW4E
 Specifications
General Description
 Dimension
Weight when fully
Extension Connection Cable
Mounted
 Characteristics
 Cards Installed in the Slots of the Hybrid IP-PBX
Maximum Optional Service Cards
System Capacity
 Card Type Maximum Number Installed KX-TDA100 KX-TDA200
MPR
LCOT4 LCOT8 LCOT16 DID8 BRI4
BRI8 PRI23 PRI30 IP-GW4 IP-GW4E
 Card Type Maximum Number
Cards Mounted on Other Optional Service Cards
Card Type Maximum Number Mounted on KX-TDA100 KX-TDA200
 Maximum Terminal Equipment
APT IP-PT
 MEC Card Calculation
MEC Card Calculation
Calculation Example KX-TDA100
Equipment Type MEC Figure
 Power Supply Unit Selection
Load Figure Calculation
PSU Capacity
Equipment Type Load Figure
 Calculation Example KX-TDA200
 Specifications
 Section Installation
 Before Installation
Before Installation
Safety Installation Instructions
Installation Precautions
 Before Installation
 Unpacking
Installation of the Hybrid IP-PBX
KX-TDA100 KX-TDA200
 Names and Locations
Inside View
 Opening/Closing the Front Cover
Opening the Front Cover
 Closing the Front Cover
 Installing/Replacing the Power Supply Unit
Accessories and User-supplied Items
Safety Instructions
Accessories included Screws ×
 Installing the Power Supply Unit
 Replacing the Power Supply Unit
 Replace the PSU
 Frame Earth Connection
Connect the frame of the Hybrid IP-PBX to earth
 Backup Battery Connection
Backup Power Supply Duration
User-supplied Items
Examples
 Connecting Backup Batteries
 Installing/Removing the Optional Service Cards
Installing Optional Service Cards
 Back Board Release Lever
 Covering the Blank Slots
 Handling of the Cables
 Removing the Optional Service Cards
 Types of Connectors
Connector Type Pin Number Used for
CTI-LINK KX-TDA0410
BNC
 MPR USB
 When connecting a BRI card
When connecting a T1/E1/PRI/IP-GW16/IP-EXT16 card
Attaching a Ferrite Core
 When connecting an extension card
 Fastening Amphenol Connector
 Amphenol Connector Pin Assignment Chart
LCOT4 LCOT8 LCOT16 DID8 DHLC8 DLC8 DLC16 MSLC16 SLC8
 Wall Mounting KX-TDA200
 Installation of the Hybrid IP-PBX
 Wall Mounting KX-TDA100
Wall
 Installation of the Hybrid IP-PBX
 Floor Standing KX-TDA200 Only
 TOP Front
 Surge Protector Installation
Installation
Overview
IP-PBX SLT PT
 Installation of an Earth Rod
Outside Installation
IP-PBX
 Installation of the Hybrid IP-PBX
 MPR Card
Information about the Main Processing Card
USB BGM/MOH
 Batt Alarm
SD Access
LED Indications
Indication Colour Description
 MEC Card KX-TDA0105
 RMT Card KX-TDA0196
 Information about the Trunk Cards
LED
 Amphenol Connector
Signal Name Function
Pin Assignments
Card Status
 2 DID8 Card KX-TDA0182
 LED Indications
 Switch Settings on LCOT8/LCOT16 cards
Switch Type Usage and Status Definition
3 CID/PAY8 Card KX-TDA0189
DIP
 4 CID8 Card KX-TDA0193
 5 E&M8 Card KX-TDA0184
 T1A
R1A
SGA
SGB
 LED Indications
 Switch Settings
6 T1 Card KX-TDA0187
 RJ45 Connector for Extension Use
RJ45 Connector for Trunk Use
Signal Name Level Function
 Maximum Cabling Distance of Extension Connection
Sync
 BNC TX
7 E1 Card KX-TDA0188
BNC RX
 BNC coaxial Connector TX
 BNC coaxial Connector RX
 8 BRI4 Card KX-TDA0284 and BRI8 Card KX-TDA0288
 TX1
RX2
RX1
TX2
 Line LED Pattern
Line
Master Clock LED Pattern
OFF
 Maximum Cabling Distance of S0 Bus Connection
 9 PRI30 Card KX-TDA0290CE/CJ
 Switch Settings
 Link
 Maximum Cabling Distance of Extension Connection
 10 PRI23 Card KX-TDA0290
 Pin Assignments
 Maximum Cabling Distance of Extension Connection
 Signal Name Input I/Output O Function
RJ45 Connector 10BASE-T
IP-GW4 Card KX-TDA0480
 Alarm
Online
IAM Busy
Data
 RJ45 Connector 10BASE-T/100BASE-TX
IP-GW4E Card KX-TDA0484
 OFF
 IP-GW16 Card KX-TDA0490
 LED Indications
 Information about the Extension Cards
CSIF4 Card KX-TDA0143 and CSIF8 Card KX-TDA0144
 Powh
RJ45 Connector
Powl
 DHLC8 Card KX-TDA0170
 D2A
D1A
D2B
D1B
 LED Indications
 3 DLC8 Card KX-TDA0171
 Data port 1 Low
 4 DLC16 Card KX-TDA0172
 D2I
D1I
D2J
D1J
 5 SLC8 Card KX-TDA0173
 Pin Assignments
 EXT-CID Card KX-TDA0168
 7 SLC16 Card KX-TDA0174 and MSLC16 Card KX- TDA0175
 Ring port Tip port 17-25 Reserved 42-50
 IP-EXT16 Card KX-TDA0470
 Online
 Information about the Other Cards
Accessories included none User-supplied not included none
1 OPB3 Card KX-TDA0190
 User-supplied not included Copper wire
2 DPH4 Card KX-TDA0161
 Pin Terminal Block
DP4
DP3
DP2
 3 DPH2 Card KX-TDA0162
 Pin Assignments
 Path Doorphone Call Path
 4 EIO4 Card KX-TDA0164
 Pin Assignments
 External Sensor
Connection Diagram
External Relay
 ECHO16 Card KX-TDA0166
 6 MSG4 Card KX-TDA0191
 CTI-LINK Card KX-TDA0410
 Link Status
 PT-interface CS
Connection of Extensions
DSS Console
 Using a Modular T-Adaptor
Parallel Connection of the Extensions
With APT
With DPT
 Using an EXtra Device Port
With KX-T7600 Series DPT except KX-T7665
Dptslt
With Other DPT except KX-T7560 and KX-T7565
 With KX-T7600 Series DPT except KX-T7600E Series
Digital EXtra Device Port Digital XDP Connection
Back View of DPTs
 To TEL To Main Unit
 With KX-T7600E Series DPT
 Connecting to a Slave DPT
 Connecting to a Master DPT
 First Party Call Control CTI Connection
 RF Specification
Connection of Dect Portable Stations
Overview
CS Cell Station KX-TDA0142CE/KX-TDA0141CE
 Equipment Distance
 Procedure Overview
Investigate the installation site
Prepare for site survey
Conduct the site survey
 Finish the site survey
Mount the CS on the wall
 Site Planning
Characteristics of Radio Waves
Understanding Radio Waves
 Object Material Transmission Tendency
 CS Coverage Area
Radio Signal Strength Levels
Site Survey Preparation
 CS installation plan
Example Installing in a Room Separated by Interior Walls
Things to take note
 Before Site Survey
Checking the CS ID Number
Assigning the CS ID Number to the PS
CS No
 Using the KX-TD7590 To enter letters
 Setting and Installing the CS Temporarily for Site Survey
DIP Switch
 For users in the United Kingdom
 Site Survey Using the KX-TCA255/KX-TD7590
Testing the Radio Signal Strength
 PS CH0
 Channel no
 Referring to the Stored Scan Data
Using the KX-TD7590 Log No
Clearing the Stored Scan Data
 After Site Survey
 Connecting a Cell Station to the Hybrid IP-PBX
Using a Csif Card
Accessories and User-supplied Items for the CS
User-supplied not included RJ11 connector
 Using a DHLC/DLC Card
 Connecting the CS
 For the KX-TDA0142CE User only
 Administrator Level
Using the KX-TCA155/KX-TCA255
Registering the PS
PS Registration
 System Lock Password /OK
System Lock Password
Using the KX-TD7580
 Setting the PIN for Hybrid IP-PBX
Changing the Display Language of the PS
 PS Termination
691
Handset PIN
 Testing the Operation
 Wall Mounting
 Install a screw here 71 mm
Reference for Wall Mounting
 KX-TDA0142 Using a Csif Card
KX-TDA0141 Using a DHLC/DLC Card
Connection of 2.4 GHz Portable Stations
CS Cell Station KX-TDA0142/KX-TDA0141
 Connection of 2.4 GHz Portable Stations
 Using the KX-TD7690
Using the KX-TD7680
Prepare the CS for site survey
 Finish the site survey
 Site Planning
 Object Material Transmission Tendency
 CS Coverage Area
 Example Installing in a Room Separated by Interior Walls
 CS Number Switch Radio Signal Test Switch CS no CS no CS no
 Connection of 2.4 GHz Portable Stations
 Site Survey
Scan Data No
 PS CS NO.1 LEVEL12
 Scan Data No
 Deleting the Stored Scan Data
 After Site Survey
 Connecting a Cell Station to the Hybrid IP-PBX
 Using a DHLC/DLC Card
 Connecting the CS
 Entering the System Programming Mode
PT Administrator Level
PS Using the KX-TD7680
System Setting Menu
 When the PS has not been registered yet
 Setting the System Lock
 Setting the PIN for PS Using the KX-TD7680
692
 System
 Wall Mounting
 Reference for Wall Mounting
 Installing the Doorphone KX-T30865
Maximum Cabling Distance
 Connection
 Installation Manual
 Connection of Peripherals
Connection of Peripherals
BGM
 Connection Charts
Pager
PC/Printer via RS-232C
Pin Assignments
 For connecting a printer/PC with a 25-pin RS-232C connector
RS-232C Signals
Signal Ground SG
Receive Data RXD…input
 PC/CTI Server via USB version
Vbus
USB D
USB D+
 Power Failure Connections
Power Failure Connections
Using Analogue Trunk Card and Extension Card
 RJ11 Connector Pin Assignments for Analogue Trunk Card
RJ11 Connector Pin Assignments for Extension Card
PFT Ports 1 Signal Name Function
PFT Ports 3 and 4 for LCOT16 card only Signal Name Function
 Switch Settings
Using BRI Card
RJ45 Connector Line 1 Pin Assignments
 RJ45 Connector Line 2 Pin Assignments
 Starting the Hybrid IP-PBX
Starting the Hybrid IP-PBX
 Confirming the Trunk Connection
RUN
 Section Guide for the KX-TDA Maintenance Console
 KX-TDA Maintenance Console*1
Overview
 Connection
Connection
Serial Interface Connection
LAN Connection via CTI-LINK Card
 External Modem Connection
SD TXD RD RXD DR DSR ER DTR
 Installation of the KX-TDA Maintenance Console
Installing and Starting the KX-TDA Maintenance Console
Password Security
System Requirements
 Installing the KX-TDA Maintenance Console
Start the KX-TDA Maintenance Console from the Start menu
 When country/area data do not match
 Installation of the KX-TDA Maintenance Console
 Section Troubleshooting
 Troubleshooting
Installation
 Problem Probable Cause Solution
 Cause
 Trunk is connected to the T2/R1
 Operation
 Problem Probable Cause Solution
 Using the Reset Button
Operation
 Error Log Display Format
Troubleshooting by Error Log
Description
 Description
 List of Errors and Solutions
Error Code Error Message
SLC, CSIF, LCOT, T1, E1
BRI, PRI, OPB3, E&M, IP
 System Start-up and On-line Operation
 Probable Cause Solution
 Probable Cause Solution
 ROM NG
CSIF, T1, E1, BRI, PRI
OPB3, CTI-LINK, E&M
RAM NG IP-GW, DID, SLC8, IP
 MPR-LPR CSIF, T1, E1, BRI, PRI
 IP-GW Sdram
IP-GW Dpram
 IP-PT SUB-CPU
 Probable Cause Solution
 Probable Cause Solution
 Section Appendix
 New Contents
Changed Contents
Revision History
Pmpr Software File Version
 Pmpr Software File Version
 Pmpr Software File Version
 Index
 Numerics
 PSU
 PSU-L PSU-M PSU-S
 Index