Calculation Example (KX-TDA200)

 

 

 

 

1.4 Specifications

 

 

 

 

Calculation Example (KX-TDA200)

 

 

 

 

 

 

 

 

Equipment Type

Load Figure

 

 

 

 

 

 

KX-T7600 series DPT

 

48 units

48

 

 

 

 

 

 

Other DPT

 

2 units

8

 

 

 

 

 

 

SLC16

 

1 card

16

 

 

 

 

 

 

MSLC16

 

1 card

16

 

 

 

 

 

 

VPS

 

8 ports

8

 

 

 

 

 

 

Total

 

 

96

 

 

 

 

 

The total load figure is 96. As this is between 64 and 128, you should install the PSU-M. But if you expect expansion in the future, it may be better to install the PSU-L. There is no harm in installing a PSU that is larger than is required for the current configuration.