6. MENU FUNCTIONS

When the function is selected the mower will immediately follow the boundary wire, guide 1 or guide 2, depending on which one it finds first, in to the charging station. If there is a passage and the mower can not run through it, the Corridor width value is set too high. When Test IN is activated, the mower runs at the greatest distance from the wire that the selected corridor width permits.

The adjacent picture shows how Automower® negotiates a passage when a value of 8 is set for the Corridor width, but not when a value of 10 is set.

8

10

IMPORTANT INFORMATION

When Test IN (3-2-4)is used, the house icon on the display will come on and the mower will remain in the charging station. Press the Home button to return to operations.

Test OUT (3-2-5)

The Test OUT (3-2-5)function is used to try different charge exit settings and to find out how far it is from the charging station to a remote area.

To test the settings for Follow loop out (3-2-1):

Set Proportion to 100 % for the most remote area to be tested and 0 % for the other areas. Place Automower® in the charging station and select Test OUT (3-2-5). The mower will now leave the charging station directly according to the stated direction and start mowing after the stated distance. Reset the Proportion values when testing is finished.

To find out the distance from the charging station to a remote area:

State a distance that easily exceeds the true distance. The maximum distance that can be stated is 500 metres. Set Proportion to 100 % for the areas where the distance is to be measured and 0 % for the other areas. Place Automower® in the charging station and select Test OUT (3-2-5). The mower will now leave the charging station directly according to the stated direction. The distance will be shown on the display, stated in metres, as the mower runs. Stop the mower after the required distance and read the distance. Enter the number of metres shown in Distance for the area in question. Reset the Proportion values when testing is finished.

Follow loop out

Follow loop in

Corridor width

Test IN

Test OUT

3-2-4

54 - English