Removing the BioClip plug

Maintenance

Removing the BioClip plug

To change a Combi deck from the BioClip function to a cutting deck with rear ejection, remove the BioClip plug, which is located under the unit.

Put the unit in the service position, see Placing in the service position.

Combi 94

Loosen the knob and the bolts holding the BioClip plug and remove the plug.

Replace the unit in normal position. Fit the BioClip plug in the reverse order.

Combi 103

Remove the three screws holding the BioClip plug, and remove the plug.

Tip: Fit three full-thread screws M8x15 mm in the screw holes to protect the threads.

Replace the unit in normal position.

Fit the BioClip plug in the reverse order.

Checking the blades

To achieve the best mowing results it is important that the blades are undamaged and well-sharpened.

Check that the blades’ attachment screws are tight.

IMPORTANT INFORMATION Replacing or sharpening the blades should be conducted by an authorised service workshop.

The blades should be balanced after sharpening.

Damaged blades should be replaced when hitting obstacles that result in a breakdown. Let the service centre assess whether the blade can be sharpened or must be replaced.