Troubleshooting tables
Use the troubleshooting tables to find solutions to problems that have identifiable
symptoms. See the Problem Determination and Service Guide on the IBM System x

Documentation CD for more detailed troubleshooting information. If you cannot find

a problem in these tables, run the diagnostic programs (see “Running the diagnostic

programs” in the Problem Determination and Service Guide).
If you have just added new software or a new optional device and the server is not
working, complete the following steps before you use the troubleshooting tables:
1. Check the system-error LED on the operator information panel (see Chapter 3,
“Server controls, LEDs, and power,” on page 21).
2. Remove the software or device that you just added.
3. Run the diagnostic tests to determine whether the server is running correctly.

4. Reinstall the new software or new device.

CD or DVD drive problems

v Follow the suggested actions in the order in which they are listed in the Action column until the problem

is solved.

v See the parts listing in the Problem Determination and Service Guide to determine which components are

customer replaceable units (CRU) and which components are field replaceable units (FRU).

v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a

trained service technician.
Symptom Action
The CD or DVD drive is not
recognized.
1. Make sure that:
v The IDE channel to which the CD or DVD drive is attached (primary) is
enabled in the Configuration/Setup Utility program.
v All cables and jumpers are installed correctly.
v The correct device driver is installed for the CD or DVD drive.

2. Run the CD, CD-RW, or DVD drive diagnostic programs.

3. Reseat the following components:
a. CD or DVD drive

b. CD or DVD interface board cable

4. Replace the following components one at a time, in the order shown, restarting

the server each time:
a. CD or DVD drive
b. CD or DVD drive interface board cable
c. CD or DVD interface board
d. (Trained service technician only) System board

A CD or DVD is not working

correctly.
1. Clean the CD or DVD.
2. Run the CD or DVD drive diagnostic programs.
3. Reseat the CD or DVD drive.
4. Replace the CD or DVD drive.
The CD or DVD drive tray is not
working.
1. Make sure that the server is turned on.
2. Insert the end of a straightened paper clip into the manual tray-release
opening.
3. Reseat the CD or DVD drive.

4. Replace the CD or DVD drive.

Chapter 5. Solving problems 37