Diagnostic Error Code FRU/Action
001-278-XXX
System IRQ11 failure
1. Device on IRQ11
2. System board
001-279-XXX
System IRQ12 failure
1. Device on IRQ12
2. System board
001-280-XXX
System IRQ13 failure
1. Device on IRQ13
2. System board
001-281-XXX
System IRQ14
(hard disk drive) failure
1. Hard disk drive cable
2. Hard disk drive
3. System board
001-282-XXX
System IRQ15 failure
1. Device on IRQ15
2. System board
001-286-XXX
001-287-XXX
001-288-XXX
System Timer failure
1. System board
001-292-XXX
System CMOS
RAM error
1. Run Setup and re-test
2. System board
001-293-XXX
System CMOS Battery
1. Battery
2. System board
001-298-XXX
System RTC date/time update failure
1. Flash the system. See “Flash update
procedures” on page 148
2. System board
001-299-XXX
System RTC periodic interrupt failure
1. System board
001-300-XXX
System RTC Alarm failure
1. System board
001-301-XXX
System RTC Century byte error
1. Flash the system. See “Flash update
procedures” on page 148
2. System board
005-000-XXX
Video Test Passed
1. No action
005-00X-XXX
Video error
1. Video card, if installed
2. System board
005-010-XXX
005-011-XXX
005-012-XXX
005-013-XXX
Video Signal failure
1. Video card, if installed
2. System board
005-016-XXX
Video Simple Pattern
test failure
1. Video Ram
2. Video card, if installed
3. System board
005-024-XXX
Video Addressing test failure
1. Video card, if installed
2. System board
Chapter 7. Symptom-to-FRU Index 53