Diagnostic Error Code FRU/Action
086-197-XXX
Mouse Port interface test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
086-198-XXX
Mouse Port interface test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Go to “Undetermined problems” on page
89
086-199-XXX
Mouse Port interface test failed, cause
unknown
1. Go to “Undetermined problems” on page
89
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Replace component under function test
089-000-XXX
Microprocessor Test Passed
1. No action
089-XXX-XXX
Microprocessor failure
1. Microprocessor(s)
2. System board
089-195-XXX
Microprocessor Test aborted by user
1. Information
2. Re-start the test, if necessary
089-196-XXX
Microprocessor test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
089-197-XXX
Microprocessor test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
089-198-XXX
Microprocessor test aborted
1. Flash the system. See “Flash update
procedures” on page 148
2. Go to “Undetermined problems” on page
89
089-199-XXX
Microprocessor test failed, cause unknown
1. Go to “Undetermined problems” on page
89
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Replace component under function test

Chapter 7. Symptom-to-FRU Index 65